Iterative camera calibration method using ray tracing and entrance pupil center constraints for phase measuring profilometry

To address the challenge of insufficient camera calibration accuracy in high-precision 3D measurement, this paper proposes an iterative method using ray tracing and entrance pupil center constraints. The entrance pupil center is estimated via ray tracing and introduced as a constraint, while outlier control points are removed using the 3<i>σ</i> criterion. Vision ray parameters are iteratively optimized with the Levenberg-Marquardt algorithm. Experimental results on a 120 mm metal bearing show that the proposed method significantly reduces reconstruction error: RMS decreases from 0.20 to 0.07 mm and PV from 1.39 to 0.76 mm, approaching the performance of coordinate measuring machines.

Authors

Publication Details

Journal
Applied Optics
Published
2025-11-07
DOI
https://doi.org/10.1364/ao.575926
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Iterative camera calibration method using ray tracing and entrance pupil center constraints for phase measuring profilometry

Zhihua Zhu, Xinwei Zhang, Lei Xu, Sheng Yuan et al.
Applied Optics
Optical measurement and interference techniques
article

Iterative camera calibration method using ray tracing and entrance pupil center constraints for phase measuring profilometry

Zhihua Zhu, Xinwei Zhang, Lei Xu, Sheng Yuan, Tiebu Bamu
article en

Abstract

To address the challenge of insufficient camera calibration accuracy in high-precision 3D measurement, this paper proposes an iterative method using ray tracing and entrance pupil center constraints. The entrance pupil center is estimated via ray tracing and introduced as a constraint, while outlier control points are removed using the 3<i>σ</i> criterion. Vision ray parameters are iteratively optimized with the Levenberg-Marquardt algorithm. Experimental results on a 120 mm metal bearing show that the proposed method significantly reduces reconstruction error: RMS decreases from 0.20 to 0.07 mm and PV from 1.39 to 0.76 mm, approaching the performance of coordinate measuring machines.

Applied OpticsVol. 64(34)
Openalex Percentile: Top 66%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Iterative camera calibration method using ray tracing and entrance pupil center constraints for phase measuring profilometry — Zhihua Zhu, Xinwei Zhang, et al. · Applied Optics (2025) | TGRS Research Map | TGRS