High-Performance hybrid solar system with V-shaped Receiver: Dual concentration and microchannel cooling approach

• New hybrid CPV system integrating Poly-PV and 3 J cells with dual optical concentrators. • Optical-thermal coupling using Fresnel lenses and PTCs for improved energy capture. • Advanced CFD-based conjugate heat transfer and exergy analysis via ANSYS Fluent. • Enhanced cooling strategy ensures high efficiency and thermal stability under high flux. Meeting the growing demand for renewable energy is crucial to ensure a reliable power supply and mitigate climate change, especially given the persistent reliance on fossil fuels. Solar photovoltaic (PV) technology, a scalable and clean energy solution, is projected to provide between 30 % to 50 % of global electricity by 2050 due to its sustainability and availability. This research work addresses the critical gap in hybrid solar technologies by introducing a new approach of integrating polycrystalline photovoltaic (Poly-PV) modules and triple-junction (3J) cells within a single framework. The Poly-PV modules, arranged in a V-shaped layout, are illuminated by a parabolic trough collector, yielding a low concentration ratio of solar irradiance, according to its limitations, of approximately 9.13X. At the same time, the 3J cells receive a highly concentrated solar flux of 400X via a Fresnel lens optical arrangement. For safer operation and better performance under concentrated irradiance, advanced thermal management is implemented through microchannel cooling devices for each cell type. A conjugate heat transfer model, solved via ANSYS Fluent, evaluates the system’s thermal and hydraulic behavior under this proposed combined optical arrangement of parabolic trough concentrator (PTC) and Fresnel lens. Complementing the energy analysis, an exergy assessment quantifies efficiency losses via exergy destruction and entropy generation, offering comprehensive insight into the system’s thermodynamic performance. The proposed hybrid system achieved electrical efficiency of up to 16.3 % for Poly-PV and 43.8 % for 3J cells, with exergy efficiencies peaking at 10,4% under a flow rate of 4 L/hr. The numerical model was validated through comparison with previously published experimental results, confirming its reliability and demonstrating that the proposed configuration significantly enhances both efficiency and thermal management compared with conventional CPV/T systems.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2025-11-07
DOI
https://doi.org/10.1016/j.enconman.2025.120740
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Performance hybrid solar system with V-shaped Receiver: Dual concentration and microchannel cooling approach

D. Santana, Sridhar Sripadmanabhan Indira, Abdallah Y.M. Ali, Hesham I. Elqady
Energy Conversion and Management
Solar Thermal and Photovoltaic Systems
article

High-Performance hybrid solar system with V-shaped Receiver: Dual concentration and microchannel cooling approach

D. Santana, Sridhar Sripadmanabhan Indira, Abdallah Y.M. Ali, Hesham I. Elqady
article en

Abstract

• New hybrid CPV system integrating Poly-PV and 3 J cells with dual optical concentrators. • Optical-thermal coupling using Fresnel lenses and PTCs for improved energy capture. • Advanced CFD-based conjugate heat transfer and exergy analysis via ANSYS Fluent. • Enhanced cooling strategy ensures high efficiency and thermal stability under high flux. Meeting the growing demand for renewable energy is crucial to ensure a reliable power supply and mitigate climate change, especially given the persistent reliance on fossil fuels. Solar photovoltaic (PV) technology, a scalable and clean energy solution, is projected to provide between 30 % to 50 % of global electricity by 2050 due to its sustainability and availability. This research work addresses the critical gap in hybrid solar technologies by introducing a new approach of integrating polycrystalline photovoltaic (Poly-PV) modules and triple-junction (3J) cells within a single framework. The Poly-PV modules, arranged in a V-shaped layout, are illuminated by a parabolic trough collector, yielding a low concentration ratio of solar irradiance, according to its limitations, of approximately 9.13X. At the same time, the 3J cells receive a highly concentrated solar flux of 400X via a Fresnel lens optical arrangement. For safer operation and better performance under concentrated irradiance, advanced thermal management is implemented through microchannel cooling devices for each cell type. A conjugate heat transfer model, solved via ANSYS Fluent, evaluates the system’s thermal and hydraulic behavior under this proposed combined optical arrangement of parabolic trough concentrator (PTC) and Fresnel lens. Complementing the energy analysis, an exergy assessment quantifies efficiency losses via exergy destruction and entropy generation, offering comprehensive insight into the system’s thermodynamic performance. The proposed hybrid system achieved electrical efficiency of up to 16.3 % for Poly-PV and 43.8 % for 3J cells, with exergy efficiencies peaking at 10,4% under a flow rate of 4 L/hr. The numerical model was validated through comparison with previously published experimental results, confirming its reliability and demonstrating that the proposed configuration significantly enhances both efficiency and thermal management compared with conventional CPV/T systems.

Energy Conversion and ManagementVol. 348
University of Ljubljana (SI), Universidad Carlos III de Madrid (ES), Universiti Teknologi MARA (MY), Aswan University (EG)
Openalex Percentile: Top 77%
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.