Experimental study of a Peltier cooler coupled to a thermosiphon heat sink

This paper describes an experiment investigation of Peltier water cooler that modified by adding a thermosiphon to enhance heat dissipation from hot junction. The thermosiphon is worked by natural circulation and working three different are tested to explore its effectiveness, which water, kerosene, and ethylene glycol solution (50/50 mixture of distilled water). Experimental work is conducted using domestic Peltier water cooler with a 760 g water tank capacity. The thermosiphon unit is added as a modification to the traditional finned heat sink connected to fan. Two different arrangements of thermosiphon are investigated, one with single riser tube, while the other has two riser tubes. The results indicates that the design with single riser tube show stable operation and gives efficient heat dissipation rather that the dual riser tube. The findings also revealed that kerosene is the best fluid to use in increasing the coefficient of performance in the system.

Authors

Institutions

Publication Details

Journal
Thermal Science
Published
2025-01-01
DOI
https://doi.org/10.2298/tsci250607188d
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study of a Peltier cooler coupled to a thermosiphon heat sink

Walaa Sabbar, Sabreen A. Abood, Safaa Hameed Faisal, Zinah Dawood
Thermal Science
Heat Transfer and Boiling Studies
article

Experimental study of a Peltier cooler coupled to a thermosiphon heat sink

Walaa Sabbar, Sabreen A. Abood, Safaa Hameed Faisal, Zinah Dawood
article en

Abstract

This paper describes an experiment investigation of Peltier water cooler that modified by adding a thermosiphon to enhance heat dissipation from hot junction. The thermosiphon is worked by natural circulation and working three different are tested to explore its effectiveness, which water, kerosene, and ethylene glycol solution (50/50 mixture of distilled water). Experimental work is conducted using domestic Peltier water cooler with a 760 g water tank capacity. The thermosiphon unit is added as a modification to the traditional finned heat sink connected to fan. Two different arrangements of thermosiphon are investigated, one with single riser tube, while the other has two riser tubes. The results indicates that the design with single riser tube show stable operation and gives efficient heat dissipation rather that the dual riser tube. The findings also revealed that kerosene is the best fluid to use in increasing the coefficient of performance in the system.

Thermal Science(00)
Shatt Al-Arab University College (IQ), Southern Technical University (IQ)
Openalex Percentile: Top 65%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental study of a Peltier cooler coupled to a thermosiphon heat sink — Walaa Sabbar, Sabreen A. Abood, et al. · Thermal Science (2025) | TGRS Research Map | TGRS