Complementary liquid and gas chromatographic-mass spectrometric methods for detecting residual impurities in Cyrene, a sustainable bio-derived solvent
Cyrene™ (dihydrolevoglucosenone) is a biomass derived solvent, which has generated significant interest as an attractive green alternative to traditional dipolar aprotic solvents. However, as with other bio-derived solvents, residual impurities from the production process can be difficult to fully remove from the final commercial product, limiting potential applications. A combined liquid chromatography-diode array UV absorbance-electrospray ionisation mass spectrometric (LC-DAD-ESI-MS) method is presented for the simultaneous analysis of residual process-derived impurities in commercially sourced Cyrene, allowing detection of UV-active compounds <i>via</i> diode array detection and non-UV-active compounds <i>via</i> mass spectrometry. Chromatographic separation of Cyrene from residual impurities was achieved in under 12 minutes using a gradient reversed-phase separation, with combined UV absorbance and MS detection, allowing for the determination of the three most abundant residual impurities in Cyrene, namely levoglucosenone (LGO), 2-methoxyphenol (2MP) and sulfolane. Limits of detection (LOD) were 0.02 mg L<sup>-1</sup> for both LGO and 2MP by UV absorbance, and 0.27 mg L<sup>-1</sup> for sulfolane by ESI-MS. Intra-day and inter-day precision expressed as relative standard deviation (RSD), were always less than 6%, and the method showed excellent linearity, <i>R</i><sup>2</sup> ≥ 0.9954, over a concentration range of 0.31-20.00 mg L<sup>-1</sup> for all three major impurities. Further for inter-method comparison a complimentary gas chromatography-mass spectrometry (GC-MS) method was developed for the same target Cyrene impurities using a DB-WAX Ultra Inert capillary column. Limits of detection (LOD) were 0.13 mg L<sup>-1</sup> for LGO, 0.07 mg L<sup>-1</sup> for 2MP, and 0.11 mg L<sup>-1</sup> for sulfolane. For commercial Cyrene samples the two methods provided cross-validatory comparative results for the three impurities of between 3% and 9% of each other when using the external calibration method. This study therefore represents the first fully validated quantitative analysis of LGO, 2MP, and sulfolane in commercial Cyrene using complementary LC-DAD-ESI-MS and GC-MS methods.
Authors
- Andrew A. Gooley (ORCID: https://orcid.org/0000-0003-3515-3069)
- Ibraam E. Mikhail (ORCID: https://orcid.org/0000-0001-5414-7401)
- Estrella Sanz Rodríguez (ORCID: https://orcid.org/0000-0003-3443-6382)
- Desmond Richardson (ORCID: https://orcid.org/0000-0001-7438-3620)
- Leo Lebanov (ORCID: https://orcid.org/0000-0002-1207-0212)
- Brett Paull (ORCID: https://orcid.org/0000-0001-6373-6582)
- Kaushalya Kankani Durage
Institutions
- University of Tasmania (AU)
Publication Details
- Journal
- Analytical Methods
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1039/d5ay01597a
- Primary Topic
- Effects and risks of endocrine disrupting chemicals
- Type
- article
- Field-Weighted Citation Impact
- 0.00