Matrix cleanup assisted extraction of phenolic pollutants from diverse wastewaters using a magnetic core shell adsorbent

This study introduces a novel and environmentally relevant sample preparation strategy for the trace-level determination of hazardous phenolic pollutants in complex wastewater matrices. Unlike conventional extraction methods that merely tolerate matrix interferences, this approach eliminates them before analyte extraction, improving selectivity and reliability. A magnetic core-shell metal-organic framework was employed to selectively adsorb interfering substances from real wastewater samples collected from pharmaceutical, municipal, and petrochemical sources. This material was characterized using scanning electron microscopy, transmission electron microscopy, energy-dispersive X-ray spectroscopy, X-ray diffraction, Fourier transform infrared spectroscopy, vibrating sample magnetometry, and Brunauer-Emmett-Teller surface analysis. Its magnetic responsiveness allowed for simple and rapid phase separation without the need for centrifugation. Following matrix cleanup, phenolic compounds were derivatized using acetic anhydride in the presence of sodium carbonate and extracted using a vortex-assisted liquid-liquid microextraction technique. The optimized method required minimal amounts of sorbent and organic solvents, improving its environmental sustainability and reducing laboratory waste. Coupled with gas chromatography and flame ionization detection, the method demonstrated excellent analytical performance, with relative standard deviations between 1.0 and 8.3% (for 10 µg L⁻<sup>1</sup>), recoveries ranging from 62 to 83%, correlation coefficients above 0.9962, and low limits of detection and quantification. Application to real wastewater samples showed recoveries between 81 and 118%, confirming the method's effectiveness in eliminating matrix interferences and accurately determining phenolic pollutants.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-07
DOI
https://doi.org/10.1038/s41598-025-24462-1
Citations
2
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
1.50

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Matrix cleanup assisted extraction of phenolic pollutants from diverse wastewaters using a magnetic core shell adsorbent

Mohammad Reza Afshar Mogaddam, Sina Mohammad Mehri, Mir Ali Farajzadeh
2 citations
Scientific Reports
Analytical chemistry methods development
1.50
article

Matrix cleanup assisted extraction of phenolic pollutants from diverse wastewaters using a magnetic core shell adsorbent

Mohammad Reza Afshar Mogaddam, Sina Mohammad Mehri, Mir Ali Farajzadeh
article en
2 citations

Abstract

This study introduces a novel and environmentally relevant sample preparation strategy for the trace-level determination of hazardous phenolic pollutants in complex wastewater matrices. Unlike conventional extraction methods that merely tolerate matrix interferences, this approach eliminates them before analyte extraction, improving selectivity and reliability. A magnetic core-shell metal-organic framework was employed to selectively adsorb interfering substances from real wastewater samples collected from pharmaceutical, municipal, and petrochemical sources. This material was characterized using scanning electron microscopy, transmission electron microscopy, energy-dispersive X-ray spectroscopy, X-ray diffraction, Fourier transform infrared spectroscopy, vibrating sample magnetometry, and Brunauer-Emmett-Teller surface analysis. Its magnetic responsiveness allowed for simple and rapid phase separation without the need for centrifugation. Following matrix cleanup, phenolic compounds were derivatized using acetic anhydride in the presence of sodium carbonate and extracted using a vortex-assisted liquid-liquid microextraction technique. The optimized method required minimal amounts of sorbent and organic solvents, improving its environmental sustainability and reducing laboratory waste. Coupled with gas chromatography and flame ionization detection, the method demonstrated excellent analytical performance, with relative standard deviations between 1.0 and 8.3% (for 10 µg L⁻<sup>1</sup>), recoveries ranging from 62 to 83%, correlation coefficients above 0.9962, and low limits of detection and quantification. Application to real wastewater samples showed recoveries between 81 and 118%, confirming the method's effectiveness in eliminating matrix interferences and accurately determining phenolic pollutants.

Scientific ReportsVol. 15(1)
Khazar University (AZ), Tabriz University of Medical Sciences (IR), University of Tabriz (IR), Near East University (CY)
University of Tabriz
Openalex Percentile: Top 16%
Analytical chemistry methods development
1.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.