A novel mobile application to examine impaired vigilance through digital means

The psychomotor vigilance task (PVT) is a three to thirty-minute test widely used to measure alertness and vigilance. However, only a few comprehensively validated PVTs are currently available through digital means, e.g., mobile devices. Thus, the present study aimed to investigate the usefulness of a novel three-minute PVT (PVT<sub>SR</sub>) delivered through a touchscreen mobile device. The present study comprised 41 healthy or undiagnosed with obstructive sleep apnea participants recruited through local advertisement in Reykjavik, Iceland between 2021 and 2022. First, participants completed an in-lab ten-minute standard PVT (PVT<sub>std</sub>) on a computer with the Inquisit software at Reykjavik University Sleep Institute. Later, the same participants completed a three-minute PVT<sub>SR</sub> in the Sleep Revolution mobile application at home. With a paired sample t-test, differences between the PVT outputs, i.e., mean reaction time (RT) and median RT, were compared between PVT<sub>std</sub> and PVT<sub>SR</sub>. In addition, effect sizes and Pearson correlations between the PVT<sub>std</sub> and PVT<sub>SR</sub> outcomes were evaluated. The average mean RT (PVT<sub>std</sub>: 350.2 ms; PVT<sub>SR</sub>: 424.1 ms) and median RT (PVT<sub>std</sub>: 334.4 ms; PVT<sub>SR</sub>: 415.2 ms) were significantly (p < 0.001) shorter in PVT<sub>std</sub> compared to PVT<sub>SR</sub>. The effect sizes for mean RT and median RT were 0.70 and 0.79, respectively. In addition, the correlations of mean RT (r = 0.96, 95% confidence interval (CI): 0.92-0.98) and median RT (r = 0.94, 95% CI: 0.89-0.97) between PVT<sub>std</sub> and PVT<sub>SR</sub> were high. Although median and mean reaction times were systematically higher when measured with the mobile application, there was a strong correlation between the methods' outcomes. After accounting for this systematic increase, the novel PVTSR approach shows potential for evaluating impaired vigilance. With future fine-tuning to adjust for the systematic delay, this readily available three-minute test could enable long-term follow-up of impaired vigilance in participants' homes.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-07
DOI
https://doi.org/10.1038/s41598-025-23155-z
Primary Topic
Sleep and Work-Related Fatigue
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel mobile application to examine impaired vigilance through digital means

Sami Nikkonen, Lisa Schmitz, Elena Richert, Hlín Kristbergsdóttir et al.
Scientific Reports
Sleep and Work-Related Fatigue
article

A novel mobile application to examine impaired vigilance through digital means

Sami Nikkonen, Lisa Schmitz, Elena Richert, Hlín Kristbergsdóttir, Juha Töyräs, Anna Sigríður Íslind, Henri Korkalainen, Kamilla Rún Jóhannsdóttir, Timo Leppänen, Erna Sif Arnardóttir, Purbanka Pahari
article en

Abstract

The psychomotor vigilance task (PVT) is a three to thirty-minute test widely used to measure alertness and vigilance. However, only a few comprehensively validated PVTs are currently available through digital means, e.g., mobile devices. Thus, the present study aimed to investigate the usefulness of a novel three-minute PVT (PVT<sub>SR</sub>) delivered through a touchscreen mobile device. The present study comprised 41 healthy or undiagnosed with obstructive sleep apnea participants recruited through local advertisement in Reykjavik, Iceland between 2021 and 2022. First, participants completed an in-lab ten-minute standard PVT (PVT<sub>std</sub>) on a computer with the Inquisit software at Reykjavik University Sleep Institute. Later, the same participants completed a three-minute PVT<sub>SR</sub> in the Sleep Revolution mobile application at home. With a paired sample t-test, differences between the PVT outputs, i.e., mean reaction time (RT) and median RT, were compared between PVT<sub>std</sub> and PVT<sub>SR</sub>. In addition, effect sizes and Pearson correlations between the PVT<sub>std</sub> and PVT<sub>SR</sub> outcomes were evaluated. The average mean RT (PVT<sub>std</sub>: 350.2 ms; PVT<sub>SR</sub>: 424.1 ms) and median RT (PVT<sub>std</sub>: 334.4 ms; PVT<sub>SR</sub>: 415.2 ms) were significantly (p < 0.001) shorter in PVT<sub>std</sub> compared to PVT<sub>SR</sub>. The effect sizes for mean RT and median RT were 0.70 and 0.79, respectively. In addition, the correlations of mean RT (r = 0.96, 95% confidence interval (CI): 0.92-0.98) and median RT (r = 0.94, 95% CI: 0.89-0.97) between PVT<sub>std</sub> and PVT<sub>SR</sub> were high. Although median and mean reaction times were systematically higher when measured with the mobile application, there was a strong correlation between the methods' outcomes. After accounting for this systematic increase, the novel PVTSR approach shows potential for evaluating impaired vigilance. With future fine-tuning to adjust for the systematic delay, this readily available three-minute test could enable long-term follow-up of impaired vigilance in participants' homes.

Scientific ReportsVol. 15(1)
Reykjavík University (IS), The University of Queensland (AU), University of Eastern Finland (FI), Kuopio University Hospital (FI), Eastern Finland Laboratory Center (FI), New York University (US)
European Commission, Kuopion Yliopistollinen Sairaala
Openalex Percentile: Top 65%
Sleep and Work-Related Fatigue
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.