Pulsed-Field Ablation Is Associated with Lower Endothelial Injury and Procedure Time Compared to Cryoballoon Ablation in Paroxysmal Atrial Fibrillation

PFA was associated with reduced endothelial injury and shorter procedural times compared with CB ablation, suggesting a potential advantage in lowering thromboembolic risk. These findings support the concept of PFA as an "endothelial sparing" ablation modality. However, the PFA procedure was associated with a significantly greater extent of myocardial injury, as reflected in circulating high-sensitivity cardiac troponin T values, compared to CB ablation (<i>p</i> = 0.007). Larger, randomized studies are warranted to confirm these results and evaluate long-term clinical outcomes.

Authors

Institutions

Publication Details

Journal
Pathophysiology
Published
2025-11-07
DOI
https://doi.org/10.3390/pathophysiology32040060
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulsed-Field Ablation Is Associated with Lower Endothelial Injury and Procedure Time Compared to Cryoballoon Ablation in Paroxysmal Atrial Fibrillation

Branka Krešić, Joško Božić, Marko Kumrić, Toni Brešković et al.
Pathophysiology
Atrial Fibrillation Management and Outcomes
article

Pulsed-Field Ablation Is Associated with Lower Endothelial Injury and Procedure Time Compared to Cryoballoon Ablation in Paroxysmal Atrial Fibrillation

Branka Krešić, Joško Božić, Marko Kumrić, Toni Brešković, Zrinka Jurišić, Ante Anić, Josip A. Borovac, Daniela Šupe‐Domić, Josip Katić
article en

Abstract

PFA was associated with reduced endothelial injury and shorter procedural times compared with CB ablation, suggesting a potential advantage in lowering thromboembolic risk. These findings support the concept of PFA as an "endothelial sparing" ablation modality. However, the PFA procedure was associated with a significantly greater extent of myocardial injury, as reflected in circulating high-sensitivity cardiac troponin T values, compared to CB ablation (<i>p</i> = 0.007). Larger, randomized studies are warranted to confirm these results and evaluate long-term clinical outcomes.

PathophysiologyVol. 32(4)
University of Split (HR)
Openalex Percentile: Top 49%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.