Evaluation of a test system using a human body model for predicting hip fracture risks in elderly falls

To address longstanding challenges in evaluating hip protectors and compliant flooring for preventing hip fractures in the elderly, test systems should replicate hip loading and accurately assess their performance. This study evaluated a thigh impact test system (drop tower) against human body model (HBM) simulations of a sideways fall. A pelvis spring-damper model representing pelvic compliance was incorporated into the system. The test system with the pelvic model reproduced HBM-derived femoral neck forces, whereas systems without it overestimated them. These results highlight the importance of incorporating a pelvic model to improve the biofidelity of thigh impact test systems.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-11-07
DOI
https://doi.org/10.1080/10255842.2025.2582052
Primary Topic
Bone health and osteoporosis research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a test system using a human body model for predicting hip fracture risks in elderly falls

Yohei Otaka, Naoki Mori, Koji Mizuno, Shunya Murakami et al.
Computer Methods in Biomechanics & Biomedical Engineering
Bone health and osteoporosis research
article

Evaluation of a test system using a human body model for predicting hip fracture risks in elderly falls

Yohei Otaka, Naoki Mori, Koji Mizuno, Shunya Murakami, Yuqing Zhao, Yuto Imaoka
article en

Abstract

To address longstanding challenges in evaluating hip protectors and compliant flooring for preventing hip fractures in the elderly, test systems should replicate hip loading and accurately assess their performance. This study evaluated a thigh impact test system (drop tower) against human body model (HBM) simulations of a sideways fall. A pelvis spring-damper model representing pelvic compliance was incorporated into the system. The test system with the pelvic model reproduced HBM-derived femoral neck forces, whereas systems without it overestimated them. These results highlight the importance of incorporating a pelvic model to improve the biofidelity of thigh impact test systems.

Computer Methods in Biomechanics & Biomedical Engineering
Fujita Health University (JP), Nagoya University (JP)
Openalex Percentile: Top 57%
Bone health and osteoporosis research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.