Acoustic simulation of cochlear implant sound to approximate the perceptual experience of electric hearing

The electrical signal processing of cochlear implants (CIs) is thought to partially explain the unnatural and unfamiliar sound impressions in recipients. To date, there are no accurate German-language sound samples available that represent how CI users perceive their CIs. The primary aim of this study was to create German-language sound samples for the sound of Cochlear Nucleus implants (Cochlear Ltd., Sydney, Australia). Furthermore, we investigated whether the simulation parameters best matched for one sentence were also accurate approximations of the CI sound when applied to two further sentences spoken by the same male speaker. Fifteen patients with single-sided deafness who had at least two years of experience with their CI were included in this study. The participants rated ten simulations based on the similarity to the sound perceived with their devices. The simulation with the best similarity score served as the starting point for optimization using a software sound-tool. On average, a score of 9.7 ± 0.5 on a scale of 1 (no similarity) to 10 (signals are identical) was achieved for the optimized simulations. Most often, a low-pass filter or a comb filter was required to optimize the simulation. The sound samples optimized for each study participant are provided in the Supplemental Material. When the parameters of the optimized simulation were applied to two further sentences (variable in content and phonemes), the similarity scores were significantly worse (mean sentence 2: 8.4 ± 1.5, Z = 3.015, p = 0.003, mean sentence 3: 8.9 ± 1.3, sign test: Z = 2.268, p = 0.048). However, when the similarity scores were considered individually for each participant, there were 4 (sentence 2) or 7 (sentence 3) participants, respectively, for whom the speech material had no influence on the similarity score.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-07
DOI
https://doi.org/10.1038/s41598-025-25711-z
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Acoustic simulation of cochlear implant sound to approximate the perceptual experience of electric hearing

Stefan K. Plontke, Anna C. Kopsch, Torsten Rahne
Scientific Reports
Hearing Loss and Rehabilitation
article

Acoustic simulation of cochlear implant sound to approximate the perceptual experience of electric hearing

Stefan K. Plontke, Anna C. Kopsch, Torsten Rahne
article en

Abstract

The electrical signal processing of cochlear implants (CIs) is thought to partially explain the unnatural and unfamiliar sound impressions in recipients. To date, there are no accurate German-language sound samples available that represent how CI users perceive their CIs. The primary aim of this study was to create German-language sound samples for the sound of Cochlear Nucleus implants (Cochlear Ltd., Sydney, Australia). Furthermore, we investigated whether the simulation parameters best matched for one sentence were also accurate approximations of the CI sound when applied to two further sentences spoken by the same male speaker. Fifteen patients with single-sided deafness who had at least two years of experience with their CI were included in this study. The participants rated ten simulations based on the similarity to the sound perceived with their devices. The simulation with the best similarity score served as the starting point for optimization using a software sound-tool. On average, a score of 9.7 ± 0.5 on a scale of 1 (no similarity) to 10 (signals are identical) was achieved for the optimized simulations. Most often, a low-pass filter or a comb filter was required to optimize the simulation. The sound samples optimized for each study participant are provided in the Supplemental Material. When the parameters of the optimized simulation were applied to two further sentences (variable in content and phonemes), the similarity scores were significantly worse (mean sentence 2: 8.4 ± 1.5, Z = 3.015, p = 0.003, mean sentence 3: 8.9 ± 1.3, sign test: Z = 2.268, p = 0.048). However, when the similarity scores were considered individually for each participant, there were 4 (sentence 2) or 7 (sentence 3) participants, respectively, for whom the speech material had no influence on the similarity score.

Scientific ReportsVol. 15(1)
Martin Luther University Halle-Wittenberg (DE)
Openalex Percentile: Top 67%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.