The Virtual Transcatheter Aortic Valve Replacement (VTAVR) framework predicts optimal device landing zones tailored to patient-specific anatomy

VTAVR, a novel simulation for Transcatheter Aortic Valve Replacement (TAVR), optimizes device placement using routine patient-specific CT angiography data. It integrates image processing, geometric reconstruction, and centerline estimation for accurate valve deployment. The framework employs a kinematic simulator to optimize valve performance by adjusting parameters like expansion area, anchoring depth, and implantation height, aiming to reduce complications such as paravalvular leaks (PVL) and left bundle branch block (LBBB). In this retrospective study (<i>N</i> = 40; pre and post TAVR), VTAVR demonstrated high fidelity with average Surface Error of pre CT simulated device versus in-vivo post CT stent frame (L2 Norm) Median: 0.633 mm; IQR= [0.216-1.37 mm]. Median post-TAVR CT device diameters were 24.4 mm [22.0-25.9 mm] at the outflow, 24.4 mm [22.5-26.0 mm] at the midflow, and 24.9 mm [22.9-26.7 mm] at the inflow, showing no significant differences compared to VTAVR simulations (<i>p</i> < 0.001). Median implantation height was 8.1 mm [6.9-10.4 mm] vs 7.2 mm [6.7-8 mm], with VTAVR predicting similar heights (<i>p</i> < 0.05). Additionally, VTAVR accurately predicted the area cover index, with a median of 101.4% [91.9-105.3%] closely matching post-TAVR CT (<i>p</i> < 0.01). The system provides assessments of peri-procedural risk factors by quantifying geometrical "safety" margins, aiming to minimize common complications such as improper implantation depth and over-expansion. VTAVR's simulation of various deployment scenarios allows clinicians to foresee and address potential complications effectively, marking a significant advance in personalized cardiac interventions through virtual, non-invasive pre-procedural optimization.

Authors

Institutions

Publication Details

Journal
npj Biomedical Innovations.
Published
2025-11-07
DOI
https://doi.org/10.1038/s44385-025-00035-9
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
1.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Virtual Transcatheter Aortic Valve Replacement (VTAVR) framework predicts optimal device landing zones tailored to patient-specific anatomy

Zahra Keshavarz‐Motamed, Mohamed Abdelkhalek
1 citations
npj Biomedical Innovations.
Cardiac Valve Diseases and Treatments
1.39
article

The Virtual Transcatheter Aortic Valve Replacement (VTAVR) framework predicts optimal device landing zones tailored to patient-specific anatomy

Zahra Keshavarz‐Motamed, Mohamed Abdelkhalek
article en
1 citations

Abstract

VTAVR, a novel simulation for Transcatheter Aortic Valve Replacement (TAVR), optimizes device placement using routine patient-specific CT angiography data. It integrates image processing, geometric reconstruction, and centerline estimation for accurate valve deployment. The framework employs a kinematic simulator to optimize valve performance by adjusting parameters like expansion area, anchoring depth, and implantation height, aiming to reduce complications such as paravalvular leaks (PVL) and left bundle branch block (LBBB). In this retrospective study (<i>N</i> = 40; pre and post TAVR), VTAVR demonstrated high fidelity with average Surface Error of pre CT simulated device versus in-vivo post CT stent frame (L2 Norm) Median: 0.633 mm; IQR= [0.216-1.37 mm]. Median post-TAVR CT device diameters were 24.4 mm [22.0-25.9 mm] at the outflow, 24.4 mm [22.5-26.0 mm] at the midflow, and 24.9 mm [22.9-26.7 mm] at the inflow, showing no significant differences compared to VTAVR simulations (<i>p</i> < 0.001). Median implantation height was 8.1 mm [6.9-10.4 mm] vs 7.2 mm [6.7-8 mm], with VTAVR predicting similar heights (<i>p</i> < 0.05). Additionally, VTAVR accurately predicted the area cover index, with a median of 101.4% [91.9-105.3%] closely matching post-TAVR CT (<i>p</i> < 0.01). The system provides assessments of peri-procedural risk factors by quantifying geometrical "safety" margins, aiming to minimize common complications such as improper implantation depth and over-expansion. VTAVR's simulation of various deployment scenarios allows clinicians to foresee and address potential complications effectively, marking a significant advance in personalized cardiac interventions through virtual, non-invasive pre-procedural optimization.

npj Biomedical Innovations.Vol. 2(1)
McMaster University (CA)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 13%
Cardiac Valve Diseases and Treatments
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.