Design and real-time sensitivity evaluation of directional eddy current probes on extracted rails

The occurrence of surface and sub-surface local damage, such as squats and studs, primarily attributed to rail-wheel contact within rail tracks, underscores the necessity for developing non-destructive testing methods. Such methods should ideally be high-speed, non-contact, and readily adaptable. Initial studies were undertaken to ascertain the optimal configurations of directional transmit and differential receiver eddy-current testing (ECT) sensors for detecting artificially induced rail defects. Discrepancies were observed in the response of the developed ECT sensors when compared to real rail damage. Consequently, this research evaluates the real-time efficacy of the original figure-8 transmit configuration with non-unity aspect ratio differential receivers against a novel dual figure-8 transmit design paired with unity aspect ratio receivers. The comparison focuses on their respective capabilities in detecting actual defects induced within rail steel samples, aiming to provide crucial insights for future in-line measurements using a trolley on a live rail network. ECT achieved a signal-to-noise ratio (SNR) exceeding 47 for rail studs, while μ -CT scans validated these results by confirming an approximate defect depth of 7.9 mm and width of 36 mm. Quantitative characterization was achieved through an evaluation of the SNR, indicating the desirability of lower frequencies for facilitating electronic data acquisition and processing. Additionally, lift-off sensitivity analysis demonstrated that the optimized probe design, operating at the optimum frequency, could detect targeted defects with up to a 10 mm lift-off distance, achieving an SNR of 5. • Directional EC probes optimized for local damage detection in rail samples. • Dual figure-8 transmit with unity receiver reduces sensitivity to steel variation. • Optimal 0.3 and 2.2 MHz frequencies identified for single and dual figure-8 transmitters paired with non-unity and unity aspect ratio receivers. • SNR > 5 at 10 mm lift-off–outperforming prior STUD scan–using same figure-8 and non-unity receiver. • μ -CT validation confirms ECT accuracy in measuring STUD defect dimensions.

Authors

Institutions

Publication Details

Journal
Measurement
Published
2025-11-07
DOI
https://doi.org/10.1016/j.measurement.2025.119611
Citations
1
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and real-time sensitivity evaluation of directional eddy current probes on extracted rails

Gulsim Rysbayeva, Roger Lewis, Meirbek Mussatayev, K. Tomlinson et al.
1 citations
Measurement
Non-Destructive Testing Techniques
0.71
article

Design and real-time sensitivity evaluation of directional eddy current probes on extracted rails

Gulsim Rysbayeva, Roger Lewis, Meirbek Mussatayev, K. Tomlinson, Damira Smagulova, Ruby Kempka, Manat Tuyenbayev, Oluwatamilore A. Adenipekun
article en
1 citations

Abstract

The occurrence of surface and sub-surface local damage, such as squats and studs, primarily attributed to rail-wheel contact within rail tracks, underscores the necessity for developing non-destructive testing methods. Such methods should ideally be high-speed, non-contact, and readily adaptable. Initial studies were undertaken to ascertain the optimal configurations of directional transmit and differential receiver eddy-current testing (ECT) sensors for detecting artificially induced rail defects. Discrepancies were observed in the response of the developed ECT sensors when compared to real rail damage. Consequently, this research evaluates the real-time efficacy of the original figure-8 transmit configuration with non-unity aspect ratio differential receivers against a novel dual figure-8 transmit design paired with unity aspect ratio receivers. The comparison focuses on their respective capabilities in detecting actual defects induced within rail steel samples, aiming to provide crucial insights for future in-line measurements using a trolley on a live rail network. ECT achieved a signal-to-noise ratio (SNR) exceeding 47 for rail studs, while μ -CT scans validated these results by confirming an approximate defect depth of 7.9 mm and width of 36 mm. Quantitative characterization was achieved through an evaluation of the SNR, indicating the desirability of lower frequencies for facilitating electronic data acquisition and processing. Additionally, lift-off sensitivity analysis demonstrated that the optimized probe design, operating at the optimum frequency, could detect targeted defects with up to a 10 mm lift-off distance, achieving an SNR of 5. • Directional EC probes optimized for local damage detection in rail samples. • Dual figure-8 transmit with unity receiver reduces sensitivity to steel variation. • Optimal 0.3 and 2.2 MHz frequencies identified for single and dual figure-8 transmitters paired with non-unity and unity aspect ratio receivers. • SNR > 5 at 10 mm lift-off–outperforming prior STUD scan–using same figure-8 and non-unity receiver. • μ -CT validation confirms ECT accuracy in measuring STUD defect dimensions.

MeasurementVol. 259
Kazakh Ablai Khan University of International Relations and World Languages (KZ), University of Bristol (GB), KazMunayGas (Kazakhstan) (KZ), Kazakh Academy of Transport and Communications named after M.Tynyshpaev (KZ), University of Sheffield (GB)
Openalex Percentile: Top 25%
Non-Destructive Testing Techniques
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.