Covalent Linker-Functionalized Nanometer-Thick Gold Film Electrodes for Noninvasive Electrochemical C-Reactive Protein Detection

C-reactive protein (CRP) serves as a vital biomarker for the real-time monitoring of inflammation, infections, and cardiovascular diseases, offering critical insights into underlying health conditions. Despite its clinical significance, the lack of noninvasive point-of-care (POC) diagnostic tools has delayed timely detection and reduced patients’ compliance. Herein, a sensitive and selective electrochemical immunosensor is developed for the noninvasive detection of CRP, providing a painless and needle-free alternative to traditional diagnostics. The sensor is constructed using a thin-film deposition method, utilizing nanometer-thick gold electrodes functionalized with a covalent linker that simplifies antibody immobilization while enhancing the stability and specificity of the detection process. The immunosensor exhibited a linear detection range of 1–35 ng/mL and a lower detection limit of 0.27 ng/mL. The immunosensor exhibits higher reproducibility with a relative standard deviation of 1.12%. Stability studies validated its long-term performance with 90% retention of the initial response after 30 days. The practical real-time utility was evaluated by performing real sample analysis using both human and artificial sweat samples. The observed results highlighted the developed immunosensor ability to perform sensitive and selective detection of CRP noninvasively at point-of-care diagnostics for timely management of inflammatory and cardiovascular conditions.

Authors

Institutions

Publication Details

Journal
ACS Applied Nano Materials
Published
2025-11-07
DOI
https://doi.org/10.1021/acsanm.5c04610
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Covalent Linker-Functionalized Nanometer-Thick Gold Film Electrodes for Noninvasive Electrochemical C-Reactive Protein Detection

Sonal Fande, Sanket Goel, Thomas George Thundat, Dharmarajan Sriram
1 citations
ACS Applied Nano Materials
Advanced biosensing and bioanalysis techniques
0.81
article

Covalent Linker-Functionalized Nanometer-Thick Gold Film Electrodes for Noninvasive Electrochemical C-Reactive Protein Detection

Sonal Fande, Sanket Goel, Thomas George Thundat, Dharmarajan Sriram
article en
1 citations

Abstract

C-reactive protein (CRP) serves as a vital biomarker for the real-time monitoring of inflammation, infections, and cardiovascular diseases, offering critical insights into underlying health conditions. Despite its clinical significance, the lack of noninvasive point-of-care (POC) diagnostic tools has delayed timely detection and reduced patients’ compliance. Herein, a sensitive and selective electrochemical immunosensor is developed for the noninvasive detection of CRP, providing a painless and needle-free alternative to traditional diagnostics. The sensor is constructed using a thin-film deposition method, utilizing nanometer-thick gold electrodes functionalized with a covalent linker that simplifies antibody immobilization while enhancing the stability and specificity of the detection process. The immunosensor exhibited a linear detection range of 1–35 ng/mL and a lower detection limit of 0.27 ng/mL. The immunosensor exhibits higher reproducibility with a relative standard deviation of 1.12%. Stability studies validated its long-term performance with 90% retention of the initial response after 30 days. The practical real-time utility was evaluated by performing real sample analysis using both human and artificial sweat samples. The observed results highlighted the developed immunosensor ability to perform sensitive and selective detection of CRP noninvasively at point-of-care diagnostics for timely management of inflammatory and cardiovascular conditions.

ACS Applied Nano MaterialsVol. 8(46)
Birla Institute of Technology and Science - Hyderabad Campus (IN), Institute of Microelectronics (CN), University at Buffalo, State University of New York (US), Birla Institute of Technology and Science, Pilani (IN)
Openalex Percentile: Top 22%
Advanced biosensing and bioanalysis techniques
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.