Wind-Induced Vibration Response of Substation Pillar-Type Switch Structures Based on Wind Tunnel Tests

To investigate the wind-induced vibration characteristics of the high-voltage Disconnect Switch (DS) system in the switching-off state and quantitatively evaluate the contribution of higher-order modes to the overall structural response, this study employed the finite element software ABAQUS to perform dynamic analysis of a refined finite element model of the treble-columns part of the DS system. The wind loads’ spectral densities corresponding to translational degrees of freedom in the [Formula: see text]- and [Formula: see text]-directions and torsional motion about the [Formula: see text]-axis were derived. These were used to obtain the generalized force mode correction coefficients for various directions and modal orders. Subsequently, the wind-induced vibration responses were calculated using the frequency domain method applied to a simplified multi-degree-of-freedom model of a serially connected three-column structure. Based on including contributions from higher-order modes, the resulting responses were combined using the Square Root of Sum of Square (SRSS) method to determine the overall distribution of wind-induced responses under different wind directions. The results reveal that the modal response distribution is relatively sparse, indicating that the effect of three-dimensional wind coupling can be neglected in the structural wind response analysis. Under the switching-off state, the resonant component of the pulsating wind response in both the [Formula: see text]- and [Formula: see text]-directions dominates over the background component. The most unfavorable wind direction angles for displacement and acceleration responses are [Formula: see text] and [Formula: see text] in the [Formula: see text]-direction, and [Formula: see text] and [Formula: see text] in the [Formula: see text]-direction, respectively. While the first-order mode is sufficient for accurate displacement response predictions, the contributions of higher-order modes must be considered for both acceleration and internal force responses.

Authors

Institutions

Publication Details

Journal
International Journal of Structural Stability and Dynamics
Published
2025-11-07
DOI
https://doi.org/10.1142/s0219455427501380
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wind-Induced Vibration Response of Substation Pillar-Type Switch Structures Based on Wind Tunnel Tests

Shuai Shao, Min Liu, Sikai Liu, Shidong Nie et al.
International Journal of Structural Stability and Dynamics
Vibration and Dynamic Analysis
article

Wind-Induced Vibration Response of Substation Pillar-Type Switch Structures Based on Wind Tunnel Tests

Shuai Shao, Min Liu, Sikai Liu, Shidong Nie, Peng Li, Jiaxing Wang, Jingyao Li
article en

Abstract

To investigate the wind-induced vibration characteristics of the high-voltage Disconnect Switch (DS) system in the switching-off state and quantitatively evaluate the contribution of higher-order modes to the overall structural response, this study employed the finite element software ABAQUS to perform dynamic analysis of a refined finite element model of the treble-columns part of the DS system. The wind loads’ spectral densities corresponding to translational degrees of freedom in the [Formula: see text]- and [Formula: see text]-directions and torsional motion about the [Formula: see text]-axis were derived. These were used to obtain the generalized force mode correction coefficients for various directions and modal orders. Subsequently, the wind-induced vibration responses were calculated using the frequency domain method applied to a simplified multi-degree-of-freedom model of a serially connected three-column structure. Based on including contributions from higher-order modes, the resulting responses were combined using the Square Root of Sum of Square (SRSS) method to determine the overall distribution of wind-induced responses under different wind directions. The results reveal that the modal response distribution is relatively sparse, indicating that the effect of three-dimensional wind coupling can be neglected in the structural wind response analysis. Under the switching-off state, the resonant component of the pulsating wind response in both the [Formula: see text]- and [Formula: see text]-directions dominates over the background component. The most unfavorable wind direction angles for displacement and acceleration responses are [Formula: see text] and [Formula: see text] in the [Formula: see text]-direction, and [Formula: see text] and [Formula: see text] in the [Formula: see text]-direction, respectively. While the first-order mode is sufficient for accurate displacement response predictions, the contributions of higher-order modes must be considered for both acceleration and internal force responses.

International Journal of Structural Stability and Dynamics
North China Electric Power University (CN), Chongqing University (CN), State Grid Corporation of China (China) (CN), China Power Engineering Consulting Group (China) (CN), Chongqing University of Technology (CN)
Openalex Percentile: Top 58%
Vibration and Dynamic Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.