Evaluation of the effectiveness of a tunnel-shaped radiation shielding system in CT-guided interventions: Reduction of scattered radiation in phantom experiment

BackgroundComputed tomography (CT) fluoroscopy provides high-resolution images and is widely used for safe and accurate procedures, but it exposes operators to high radiation doses.PurposeTo develop and evaluate a tunnel-shaped shielding system to reduce operator exposure to scattered radiation during CT fluoroscopy-guided procedures.Material and MethodsThe shield, designed based on scattered radiation distribution, consists of a semi-cylindrical leaded acrylic part and a bottom plate with a non-lead shielding board surrounding the patient. Radiation doses were measured with and without the shield using patient and operator phantoms. Dosimeters were placed at 10 locations on the operator phantom, including the eye lens, thyroid, chest, abdomen, pelvis, legs, patient-side armpit, and needle-holding hand. Percentage reductions in radiation exposure were calculated.ResultsThe tunnel-shaped shield significantly reduced radiation exposure, with dose reductions of 83%-100% at the eye lens, 88%-96% at the thyroid, 84%-95% at the upper chest, 84%-92% at the lower chest, 88%-94% at the abdomen, 91%-94% at the pelvis, 57%-68% at the upper leg, 44%-83% at the lower leg, 90%-94% at the patient-side armpit, and 73%-86% at the needle-holding hand. All reductions were statistically significant.ConclusionPhantom experiments demonstrated that the tunnel-shaped shielding system effectively reduces operator exposure to scattered radiation during CT fluoroscopy-guided procedures.

Authors

Institutions

Publication Details

Journal
Acta Radiologica
Published
2025-11-06
DOI
https://doi.org/10.1177/02841851251389937
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the effectiveness of a tunnel-shaped radiation shielding system in CT-guided interventions: Reduction of scattered radiation in phantom experiment

Miyuki Nakatani, Shuji Kariya, Yasuyuki Ono, Noboru Tanigawa et al.
Acta Radiologica
Radiation Dose and Imaging
article

Evaluation of the effectiveness of a tunnel-shaped radiation shielding system in CT-guided interventions: Reduction of scattered radiation in phantom experiment

Miyuki Nakatani, Shuji Kariya, Yasuyuki Ono, Noboru Tanigawa, Takuji Maruyama, Yutaka Ueno
article en

Abstract

BackgroundComputed tomography (CT) fluoroscopy provides high-resolution images and is widely used for safe and accurate procedures, but it exposes operators to high radiation doses.PurposeTo develop and evaluate a tunnel-shaped shielding system to reduce operator exposure to scattered radiation during CT fluoroscopy-guided procedures.Material and MethodsThe shield, designed based on scattered radiation distribution, consists of a semi-cylindrical leaded acrylic part and a bottom plate with a non-lead shielding board surrounding the patient. Radiation doses were measured with and without the shield using patient and operator phantoms. Dosimeters were placed at 10 locations on the operator phantom, including the eye lens, thyroid, chest, abdomen, pelvis, legs, patient-side armpit, and needle-holding hand. Percentage reductions in radiation exposure were calculated.ResultsThe tunnel-shaped shield significantly reduced radiation exposure, with dose reductions of 83%-100% at the eye lens, 88%-96% at the thyroid, 84%-95% at the upper chest, 84%-92% at the lower chest, 88%-94% at the abdomen, 91%-94% at the pelvis, 57%-68% at the upper leg, 44%-83% at the lower leg, 90%-94% at the patient-side armpit, and 73%-86% at the needle-holding hand. All reductions were statistically significant.ConclusionPhantom experiments demonstrated that the tunnel-shaped shielding system effectively reduces operator exposure to scattered radiation during CT fluoroscopy-guided procedures.

Acta RadiologicaVol. 67(1)
Kansai Medical University (JP)
Openalex Percentile: Top 52%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of the effectiveness of a tunnel-shaped radiation shielding system in CT-guided interventions: Reduction of scattered radiation in phantom experiment — Miyuki Nakatani, Shuji Kariya, et al. · Acta Radiologica (2025) | TGRS Research Map | TGRS