Effect of dimethyl phthalate contamination on all-silica GLAD quarter-wave plate performances
Phthalate molecular contamination, identified in the Laser Mégajoule target chamber, can severely alter porous coatings' performance, such as glancing angle deposited quarter-wave plates (QWP). QWPs could potentially be used inside this chamber to smooth the intensity of the focal spots on the target. In this study, all-silica QWP coatings were contaminated with dimethyl phthalate. Transmission was lowered due to the absorption of phthalates, and a non-uniform retardance was induced, even after a two-month storage period in air following contamination. Infrared measurements confirmed the presence of bonds associated with phthalates within the coatings due to their sorption and only partial desorption.
Authors
- Bruno Gallas (ORCID: https://orcid.org/0000-0003-4717-3948)
- C. Boscher (ORCID: https://orcid.org/0000-0002-1359-6742)
- Marcela Mireles (ORCID: https://orcid.org/0000-0003-3972-5570)
- Sara MacNally
- Marine Chorel
- Corinne Marcel (ORCID: https://orcid.org/0000-0003-0814-8096)
- Daniel Sadowski (ORCID: https://orcid.org/0000-0001-6614-8866)
- Solène Bertet
- Éric Lavastre
- Tristan Quelo
Institutions
- Sorbonne Université (FR)
- Laboratoire Médiations (FR)
- University of Rochester (US)
Publication Details
- Journal
- Applied Optics
- Published
- 2025-11-06
- DOI
- https://doi.org/10.1364/ao.575041
- Primary Topic
- Laser Material Processing Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00