Comparison between transmural puncture combined with sensor tube technique with direct puncture in invasive blood pressure monitoring: a randomized controlled trial

This study primarily aimed to compare the efficacy of the transmural puncture combined with sensor tube technique and the direct puncture technique by examining the success of radial artery cannulation performed by nurses. The study was a prospective randomized controlled study. A total of 8 neurocritical nurses performed radial arterial insertion for 91 patients using both the transmural puncture combined with sensor tube technique and the direct puncture technique in random order. The primary outcome was successful cannulation of the radial artery in 3 or less attempts. Other collected data included the total number of attempts, total time for catheter cannulation, and occurrence of complications. In comparison with the direct puncture technique, transmural puncture combined with sensor tube increased the probability of successful initial catheterization (OR 3.27, [95% CI: 1.292-8.299]; P = 0.012) and demonstrated less blood exposure (6.52% vs. 80.0%, P < 0.001, φ=-0.742). A combination of transmural puncture and a sensor tube resulted in fewer cases of extubation due to complications. Furthermore, immediate complications caused by puncture (4.34% vs. 17.78%; P = 0.039, φ=-0.215) and extubation due to complications were reduced (47.8% vs. 71.1%, P = 0.024, φ = 0.237). Transmural puncture combined with sensor tube was demonstrated to increase the success rate of the initial arterial puncture, reduce blood exposure and reduce the occurrence of complications. Therefore, the transmural puncture combined with sensor tube technique may be an acceptable option for cannulation of the radial artery.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-06
DOI
https://doi.org/10.1038/s41598-025-22883-6
Primary Topic
Vascular Procedures and Complications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison between transmural puncture combined with sensor tube technique with direct puncture in invasive blood pressure monitoring: a randomized controlled trial

Fang Chen, Yu Guo, X Y Feng, Bin Mei et al.
Scientific Reports
Vascular Procedures and Complications
article

Comparison between transmural puncture combined with sensor tube technique with direct puncture in invasive blood pressure monitoring: a randomized controlled trial

Fang Chen, Yu Guo, X Y Feng, Bin Mei, Zhifei Wang, Liu Yang, Fei Xie, Xuena Wang
article en

Abstract

This study primarily aimed to compare the efficacy of the transmural puncture combined with sensor tube technique and the direct puncture technique by examining the success of radial artery cannulation performed by nurses. The study was a prospective randomized controlled study. A total of 8 neurocritical nurses performed radial arterial insertion for 91 patients using both the transmural puncture combined with sensor tube technique and the direct puncture technique in random order. The primary outcome was successful cannulation of the radial artery in 3 or less attempts. Other collected data included the total number of attempts, total time for catheter cannulation, and occurrence of complications. In comparison with the direct puncture technique, transmural puncture combined with sensor tube increased the probability of successful initial catheterization (OR 3.27, [95% CI: 1.292-8.299]; P = 0.012) and demonstrated less blood exposure (6.52% vs. 80.0%, P < 0.001, φ=-0.742). A combination of transmural puncture and a sensor tube resulted in fewer cases of extubation due to complications. Furthermore, immediate complications caused by puncture (4.34% vs. 17.78%; P = 0.039, φ=-0.215) and extubation due to complications were reduced (47.8% vs. 71.1%, P = 0.024, φ = 0.237). Transmural puncture combined with sensor tube was demonstrated to increase the success rate of the initial arterial puncture, reduce blood exposure and reduce the occurrence of complications. Therefore, the transmural puncture combined with sensor tube technique may be an acceptable option for cannulation of the radial artery.

Scientific ReportsVol. 15(1)
Wuhan University (CN), Zhongnan Hospital of Wuhan University (CN)
Wuhan University, Zhongnan Hospital of Wuhan University, Science and Technology Program of Hubei Province
Openalex Percentile: Top 53%
Vascular Procedures and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.