High‐Temperature Heat Pump Test Bench with <i>n</i> ‐Butane (R‐600) Generating Steam

Abstract The demand for process heat significantly contributes to energy consumption, and due to the typically fossil‐based heat generation, it has a substantial contribution to Germany's greenhouse gas emissions. In order to decarbonize this sector, heat pumps generating process heat, particularly steam, are essential. This work presents a heat pump test bench using the natural refrigerant n ‐butane (R‐600). The heat pump can provide temperatures of up to 120 °C, with capacities reaching up to 125 kW th depending on the source temperature. The results are in line with those from other test benches regarding the coefficient of performance (COP). Further, the operation in three different modes is tested and evaluated: pressurized water heating (PWH), wet steam generation (WSG), and dry steam generation (DSG). The heat transfer shows a slight increase when producing steam.

Authors

Institutions

Publication Details

Journal
Chemie Ingenieur Technik
Published
2025-11-06
DOI
https://doi.org/10.1002/cite.70046
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High‐Temperature Heat Pump Test Bench with n ‐Butane (R‐600) Generating Steam

Lena Schnabel, Stefan K. Henninger, A. Bürger, Ursula Wittstadt et al.
Chemie Ingenieur Technik
Refrigeration and Air Conditioning Technologies
article

High‐Temperature Heat Pump Test Bench with n ‐Butane (R‐600) Generating Steam

Lena Schnabel, Stefan K. Henninger, A. Bürger, Ursula Wittstadt, Torsten Will, Thorsten Klahm, Lukas Joos, Sebastian Benkert
article en

Abstract

Abstract The demand for process heat significantly contributes to energy consumption, and due to the typically fossil‐based heat generation, it has a substantial contribution to Germany's greenhouse gas emissions. In order to decarbonize this sector, heat pumps generating process heat, particularly steam, are essential. This work presents a heat pump test bench using the natural refrigerant n ‐butane (R‐600). The heat pump can provide temperatures of up to 120 °C, with capacities reaching up to 125 kW th depending on the source temperature. The results are in line with those from other test benches regarding the coefficient of performance (COP). Further, the operation in three different modes is tested and evaluated: pressurized water heating (PWH), wet steam generation (WSG), and dry steam generation (DSG). The heat transfer shows a slight increase when producing steam.

Chemie Ingenieur Technik
Fraunhofer Institute for Solar Energy Systems (DE), Klinikum Links der Weser (DE), Daimler (Germany) (DE)
Openalex Percentile: Top 66%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High‐Temperature Heat Pump Test Bench with <i>n</i> ‐Butane (R‐600) Generating Steam — Lena Schnabel, Stefan K. Henninger, et al. · Chemie Ingenieur Technik (2025) | TGRS Research Map | TGRS