A preliminary experiment to verify the relationship between radon and atmospheric electric conductivity related to earthquake precursors

Atmospheric electric conductivity is considered an important factor affecting the propagation and coupling of seismic disturbance signals in the lithosphere, atmosphere, and ionosphere. During the preparation of an earthquake, substances released from the solid Earth into the atmosphere may cause changes in atmospheric electric conductivity, thereby affecting atmospheric electrical parameters. However, the specific substances that cause these changes and their extent are not fully understood. This hinders our understanding of the mechanisms that generate ionospheric anomalies before earthquakes and how earthquakes affect atmospheric electrical parameters, hindering earthquake prediction. However, atmospheric electric conductivity is usually only studied by meteorologists, and there are few continuous fixed-point observation data, with observations during earthquakes being almost non-existent. To address this gap, we developed a wide-range, high-sensitivity, high-sampling-rate, and sustainable atmospheric electric conductivity meter for seismic observation based on the Gerdien sensor and tested it in an environment with high radon concentration. The experimental results show that the Pearson correlation coefficient between radon and atmospheric electric conductivity exceeds 0.99, and the significance is less than 0.001. This indicates that radon does cause changes in atmospheric electric conductivity, and they have a strong positive correlation. High temperatures may increase the thermal motion of molecules, resulting in discrete measurement results. Finally, after analyzing the data, we suggest that high concentrations of radon enhance the ionization of the air, leading to an increase in ion pairs. This, in turn, results in a larger ion recombination coefficient. This process may cause deviations in the calculation of theoretical atmospheric electric conductivity based on radon concentration.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-06
DOI
https://doi.org/10.1038/s41598-025-21906-6
Citations
1
Primary Topic
Earthquake Detection and Analysis
Type
article
Field-Weighted Citation Impact
1.87

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A preliminary experiment to verify the relationship between radon and atmospheric electric conductivity related to earthquake precursors

Song Fu, Wenguo Xiang, Xiaohui Du, Xiongjie Zhang et al.
1 citations
Scientific Reports
Earthquake Detection and Analysis
1.87
article

A preliminary experiment to verify the relationship between radon and atmospheric electric conductivity related to earthquake precursors

Song Fu, Wenguo Xiang, Xiaohui Du, Xiongjie Zhang, ZhuangKai Wang, Guisheng Zhu, Chen Zhou, Rengui Huang
article en
1 citations

Abstract

Atmospheric electric conductivity is considered an important factor affecting the propagation and coupling of seismic disturbance signals in the lithosphere, atmosphere, and ionosphere. During the preparation of an earthquake, substances released from the solid Earth into the atmosphere may cause changes in atmospheric electric conductivity, thereby affecting atmospheric electrical parameters. However, the specific substances that cause these changes and their extent are not fully understood. This hinders our understanding of the mechanisms that generate ionospheric anomalies before earthquakes and how earthquakes affect atmospheric electrical parameters, hindering earthquake prediction. However, atmospheric electric conductivity is usually only studied by meteorologists, and there are few continuous fixed-point observation data, with observations during earthquakes being almost non-existent. To address this gap, we developed a wide-range, high-sensitivity, high-sampling-rate, and sustainable atmospheric electric conductivity meter for seismic observation based on the Gerdien sensor and tested it in an environment with high radon concentration. The experimental results show that the Pearson correlation coefficient between radon and atmospheric electric conductivity exceeds 0.99, and the significance is less than 0.001. This indicates that radon does cause changes in atmospheric electric conductivity, and they have a strong positive correlation. High temperatures may increase the thermal motion of molecules, resulting in discrete measurement results. Finally, after analyzing the data, we suggest that high concentrations of radon enhance the ionization of the air, leading to an increase in ion pairs. This, in turn, results in a larger ion recombination coefficient. This process may cause deviations in the calculation of theoretical atmospheric electric conductivity based on radon concentration.

Scientific ReportsVol. 15(1)
Jiujiang University (CN), Wuhan University (CN), Heilongjiang Earthquake Agency (CN), East China University of Technology (CN), Wuhan University of Science and Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 13%
Earthquake Detection and Analysis
1.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.