Optimizing Detection Schemes for Broadband Pump‐Probe Microscopy

Although similar to more commonly implemented single wavelength approaches, broadband pump-probe or transient absorption microscopy presents unique experimental challenges due to the simultaneous requirements of a broadband probe pulse and a small sample volume. Here we provide an in-depth analysis of broadband detection schemes and their common noise sources to provide strategies for balancing the conflicting needs of high sensitivity and low probe fluence. We show that broadband pump-probe microscopy is atypically sensitive to laser shot noise and therefore, low pump on/off modulation frequencies, on the order of 100 s of Hz to a few kHz, are essential to measure small ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mo>~</mml:mo> <mml:msup><mml:mn>10</mml:mn> <mml:mrow><mml:mo>-</mml:mo> <mml:mn>3</mml:mn></mml:mrow> </mml:msup> <mml:mo>-</mml:mo> <mml:msup><mml:mn>10</mml:mn> <mml:mrow><mml:mo>-</mml:mo> <mml:mn>4</mml:mn></mml:mrow> </mml:msup> </mml:mrow> </mml:semantics> </mml:math> ) amplitude transient spectra while remaining in the perturbative limit.

Authors

Institutions

Publication Details

Journal
Microscopy Research and Technique
Published
2025-11-06
DOI
https://doi.org/10.1002/jemt.70092
Primary Topic
Near-Field Optical Microscopy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Detection Schemes for Broadband Pump‐Probe Microscopy

Emma K. Orcutt, Erik M. Grumstrup, Skyler R. Hollinbeck, Kendall Benton
Microscopy Research and Technique
Near-Field Optical Microscopy
article

Optimizing Detection Schemes for Broadband Pump‐Probe Microscopy

Emma K. Orcutt, Erik M. Grumstrup, Skyler R. Hollinbeck, Kendall Benton
article en

Abstract

Although similar to more commonly implemented single wavelength approaches, broadband pump-probe or transient absorption microscopy presents unique experimental challenges due to the simultaneous requirements of a broadband probe pulse and a small sample volume. Here we provide an in-depth analysis of broadband detection schemes and their common noise sources to provide strategies for balancing the conflicting needs of high sensitivity and low probe fluence. We show that broadband pump-probe microscopy is atypically sensitive to laser shot noise and therefore, low pump on/off modulation frequencies, on the order of 100 s of Hz to a few kHz, are essential to measure small ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mo>~</mml:mo> <mml:msup><mml:mn>10</mml:mn> <mml:mrow><mml:mo>-</mml:mo> <mml:mn>3</mml:mn></mml:mrow> </mml:msup> <mml:mo>-</mml:mo> <mml:msup><mml:mn>10</mml:mn> <mml:mrow><mml:mo>-</mml:mo> <mml:mn>4</mml:mn></mml:mrow> </mml:msup> </mml:mrow> </mml:semantics> </mml:math> ) amplitude transient spectra while remaining in the perturbative limit.

Microscopy Research and TechniqueVol. 89(4)
Montana State University (US)
National Science Foundation, Office of Experimental Program to Stimulate Competitive Research
Openalex Percentile: Top 68%
Near-Field Optical Microscopy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimizing Detection Schemes for Broadband Pump‐Probe Microscopy — Emma K. Orcutt, Erik M. Grumstrup, et al. · Microscopy Research and Technique (2025) | TGRS Research Map | TGRS