Pseudovirus-Based Neutralization Assays as Customizable and Scalable Tools for Serological Surveillance and Immune Profiling

Neutralizing antibodies (nAbs) are key indicators of protection against SARS-CoV-2, and their measurement remains essential for monitoring vaccine responses and population immunity. While the plaque reduction neutralization test (PRNT) is the gold standard, it relies on replicative viruses and is not suited for high-throughput applications. Here, both an in-house and a commercial pseudovirus-based neutralization (PBN) assay were standardized and compared with PRNT to assess performance and concordance. The in-house PBN employed a VSV-ΔG pseudovirus encoding NanoLuc and displaying the SARS-CoV-2 Spike from the Wuhan or Omicron BA.1 variants in HEK293T-hACE2 cells, whereas the commercial assay (Integral Molecular, Philadelphia, PA, USA) used a lentiviral backbone with Renilla or GFP reporters and Wuhan or Omicron XBB.1.5/XBB.1.9 Spikes in Vero E6-ACE2-TMPRSS2 cells. Both assays showed strong correlations with PRNT, the commercial assay; moreover, they offered superior reproducibility and scalability, while the in-house version provided a cost-effective alternative suitable for BSL-2 settings. A total of 600 serum samples from vaccinated individuals were analyzed by commercial PBN at collection time points, from pre-vaccination to twelve months post-second dose, enabling large-scale screening, revealing marked differences in neutralization between Wuhan and Omicron XBB.1.5/1.9, and allowing unbiased classification of low, medium, and high responders using k-means clustering. The geometric mean titers (log<sub>10</sub> GMT) highlighted a ~1.5 log<sub>10</sub> (eightfold) reduction in neutralizing activity against Omicron, reflecting antibody waning and antigenic drift. Altogether, this study integrates assay standardization, PRNT comparison, and large-scale immune profiling, establishing a robust framework for harmonized pseudovirus-based neutralization testing.

Authors

Institutions

Publication Details

Journal
Pathogens
Published
2025-11-06
DOI
https://doi.org/10.3390/pathogens14111129
Citations
1
Primary Topic
SARS-CoV-2 and COVID-19 Research
Type
article
Field-Weighted Citation Impact
1.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pseudovirus-Based Neutralization Assays as Customizable and Scalable Tools for Serological Surveillance and Immune Profiling

Caio Bidueira Denani, Ingrid Horbach, Bruno Setatino, Gabriela Ferreira Coutinho et al.
1 citations
Pathogens
SARS-CoV-2 and COVID-19 Research
1.40
article

Pseudovirus-Based Neutralization Assays as Customizable and Scalable Tools for Serological Surveillance and Immune Profiling

Caio Bidueira Denani, Ingrid Horbach, Bruno Setatino, Gabriela Ferreira Coutinho, Denise Pereira, Waleska Dias Schwarcz, Maria de Lourdes Maia, Ivanildo P. Sousa, Clara Lucy de Vasconcellos Ferroco, Adriana de Souza Azevedo, R.C. Leite, Ewerton Alves Portela dos Santos, Janaína Reis Xavier
article en
1 citations

Abstract

Neutralizing antibodies (nAbs) are key indicators of protection against SARS-CoV-2, and their measurement remains essential for monitoring vaccine responses and population immunity. While the plaque reduction neutralization test (PRNT) is the gold standard, it relies on replicative viruses and is not suited for high-throughput applications. Here, both an in-house and a commercial pseudovirus-based neutralization (PBN) assay were standardized and compared with PRNT to assess performance and concordance. The in-house PBN employed a VSV-ΔG pseudovirus encoding NanoLuc and displaying the SARS-CoV-2 Spike from the Wuhan or Omicron BA.1 variants in HEK293T-hACE2 cells, whereas the commercial assay (Integral Molecular, Philadelphia, PA, USA) used a lentiviral backbone with Renilla or GFP reporters and Wuhan or Omicron XBB.1.5/XBB.1.9 Spikes in Vero E6-ACE2-TMPRSS2 cells. Both assays showed strong correlations with PRNT, the commercial assay; moreover, they offered superior reproducibility and scalability, while the in-house version provided a cost-effective alternative suitable for BSL-2 settings. A total of 600 serum samples from vaccinated individuals were analyzed by commercial PBN at collection time points, from pre-vaccination to twelve months post-second dose, enabling large-scale screening, revealing marked differences in neutralization between Wuhan and Omicron XBB.1.5/1.9, and allowing unbiased classification of low, medium, and high responders using k-means clustering. The geometric mean titers (log<sub>10</sub> GMT) highlighted a ~1.5 log<sub>10</sub> (eightfold) reduction in neutralizing activity against Omicron, reflecting antibody waning and antigenic drift. Altogether, this study integrates assay standardization, PRNT comparison, and large-scale immune profiling, establishing a robust framework for harmonized pseudovirus-based neutralization testing.

PathogensVol. 14(11)
Fundação Oswaldo Cruz (BR)
Universidade do Estado do Rio de Janeiro
Openalex Percentile: Top 15%
SARS-CoV-2 and COVID-19 Research
1.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.