Public Health Risks Associated with Aerosolised Pathogens from Non-potable Applications of Recycled Water

Abstract Water scarcity threatens global health and development, prompting increased adoption of recycled water. However, recycled water introduces potential health risks due to pathogenic microorganisms. Aerosol-generating applications of recycled water are particularly concerning yet understudied. This systematic literature review examined the human health risks associated with aerosols generated from non-potable applications of recycled water. Ten peer-reviewed articles from the United States, France, China, and Israel assessed infection risk using quantitative microbial risk assessment (QMRA). These studies focused on aerosolised exposure to four pathogens: Legionella pneumophila , Escherichia coli , Staphylococcus aureus , and norovirus genogroup I and II through inhalation and dermal contact. Infection risks for L. pneumophila and E. coli from toilet flushing ranged from 2.95 × 10 −6 to 8.52 × 10 −5 and 8.8 × 10 –15 to 8.3 × 10 –11 infections per person-year (ippy), respectively, all within the United States Environmental Protection Agency (USEPA) limit of 10 −4 ippy. For irrigation, risks for L. pneumophila ranged from 1 × 10 –12 to 1.3 × 10 −2 ippy and for norovirus from 1 × 10 −3 to 8.1 × 10 −3 ippy. Other applications included fountains (≥ 7.96 × 10 −4 ), cooling towers (1 × 10 −4 − 1 × 10 −2 ), dust control (1.71 × 10 −5 − 8.78 × 10 −4 ), and S. aureus through dermal contact (2.7 × 10 −7 ). Most studies estimated aerosol dose indirectly using source water pathogen concentrations and exposure scenarios, contributing to variability in predicted risks. These findings highlight the need for microbial risk assessment models incorporating direct exposure measurements to estimate pathogen concentrations in aerosols across applications.

Authors

Institutions

Publication Details

Journal
Environmental Processes
Published
2025-11-06
DOI
https://doi.org/10.1007/s40710-025-00789-9
Primary Topic
Wastewater Treatment and Reuse
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Public Health Risks Associated with Aerosolised Pathogens from Non-potable Applications of Recycled Water

Kirstin Ross, Ben van den Akker, Harriet Whiley, Lira Adiyani
Environmental Processes
Wastewater Treatment and Reuse
article

Public Health Risks Associated with Aerosolised Pathogens from Non-potable Applications of Recycled Water

Kirstin Ross, Ben van den Akker, Harriet Whiley, Lira Adiyani
article en

Abstract

Abstract Water scarcity threatens global health and development, prompting increased adoption of recycled water. However, recycled water introduces potential health risks due to pathogenic microorganisms. Aerosol-generating applications of recycled water are particularly concerning yet understudied. This systematic literature review examined the human health risks associated with aerosols generated from non-potable applications of recycled water. Ten peer-reviewed articles from the United States, France, China, and Israel assessed infection risk using quantitative microbial risk assessment (QMRA). These studies focused on aerosolised exposure to four pathogens: Legionella pneumophila , Escherichia coli , Staphylococcus aureus , and norovirus genogroup I and II through inhalation and dermal contact. Infection risks for L. pneumophila and E. coli from toilet flushing ranged from 2.95 × 10 −6 to 8.52 × 10 −5 and 8.8 × 10 –15 to 8.3 × 10 –11 infections per person-year (ippy), respectively, all within the United States Environmental Protection Agency (USEPA) limit of 10 −4 ippy. For irrigation, risks for L. pneumophila ranged from 1 × 10 –12 to 1.3 × 10 −2 ippy and for norovirus from 1 × 10 −3 to 8.1 × 10 −3 ippy. Other applications included fountains (≥ 7.96 × 10 −4 ), cooling towers (1 × 10 −4 − 1 × 10 −2 ), dust control (1.71 × 10 −5 − 8.78 × 10 −4 ), and S. aureus through dermal contact (2.7 × 10 −7 ). Most studies estimated aerosol dose indirectly using source water pathogen concentrations and exposure scenarios, contributing to variability in predicted risks. These findings highlight the need for microbial risk assessment models incorporating direct exposure measurements to estimate pathogen concentrations in aerosols across applications.

Environmental ProcessesVol. 12(4)
Flinders University (AU), University of South Australia (AU), Flinders Medical Centre (AU)
Lembaga Pengelola Dana Pendidikan
Openalex Percentile: Top 60%
Wastewater Treatment and Reuse
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.