Optimization of Gamma Image Quality Through Experimental Evaluation Using 3D-Printed Phantoms Across Energy Window Levels

Energy window selection is a critical parameter for optimizing planar gamma image quality in nuclear medicine. In this study, we developed dedicated nuclear medicine phantoms using 3D printing technology to evaluate the impact of varying energy window levels on image quality. Three types of phantoms-a Derenzo phantom with six different sphere diameters, a modified Hoffman phantom incorporating lead for attenuation, and a quadrant bar phantom with four bar thicknesses constructed from bronze filament-were fabricated using Fusion 360 and an Ultimaker S5 3D printer with PLA and bronze-based materials. Planar images were acquired using 37 MBq of Tc-99m for 60 s at energy windows centered at 122, 140, and 159 keV. Quantitative assessments included contrast-to-noise ratio (CNR), coefficient of variation (COV), peak signal-to-noise ratio (PSNR), and structural similarity index measure (SSIM), comparing all images with the 140 keV image as the reference. The results showed a consistent decline in image quality at 122 keV and 159 keV, with the highest CNR, lowest COV, and optimal PSNR/SSIM values obtained at 140 keV. In visual analysis using the quadrant bar phantom, thinner bars were more clearly discernible at 140 keV than at other energy levels. These findings demonstrate that the application of an appropriate energy window-particularly 140 keV for Tc-99m-substantially improves image quality in planar gamma imaging. The use of customized, material-specific 3D-printed phantoms also enables flexible, reproducible evaluation protocols for energy-dependent imaging optimization and quality assurance in clinical nuclear medicine.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-11-06
DOI
https://doi.org/10.3390/bioengineering12111211
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of Gamma Image Quality Through Experimental Evaluation Using 3D-Printed Phantoms Across Energy Window Levels

Min-Gwan Lee, Chanrok Park, Joo-Wan Hong
Bioengineering
Advanced X-ray and CT Imaging
article

Optimization of Gamma Image Quality Through Experimental Evaluation Using 3D-Printed Phantoms Across Energy Window Levels

Min-Gwan Lee, Chanrok Park, Joo-Wan Hong
article en

Abstract

Energy window selection is a critical parameter for optimizing planar gamma image quality in nuclear medicine. In this study, we developed dedicated nuclear medicine phantoms using 3D printing technology to evaluate the impact of varying energy window levels on image quality. Three types of phantoms-a Derenzo phantom with six different sphere diameters, a modified Hoffman phantom incorporating lead for attenuation, and a quadrant bar phantom with four bar thicknesses constructed from bronze filament-were fabricated using Fusion 360 and an Ultimaker S5 3D printer with PLA and bronze-based materials. Planar images were acquired using 37 MBq of Tc-99m for 60 s at energy windows centered at 122, 140, and 159 keV. Quantitative assessments included contrast-to-noise ratio (CNR), coefficient of variation (COV), peak signal-to-noise ratio (PSNR), and structural similarity index measure (SSIM), comparing all images with the 140 keV image as the reference. The results showed a consistent decline in image quality at 122 keV and 159 keV, with the highest CNR, lowest COV, and optimal PSNR/SSIM values obtained at 140 keV. In visual analysis using the quadrant bar phantom, thinner bars were more clearly discernible at 140 keV than at other energy levels. These findings demonstrate that the application of an appropriate energy window-particularly 140 keV for Tc-99m-substantially improves image quality in planar gamma imaging. The use of customized, material-specific 3D-printed phantoms also enables flexible, reproducible evaluation protocols for energy-dependent imaging optimization and quality assurance in clinical nuclear medicine.

BioengineeringVol. 12(11)
Eulji University (KR)
Openalex Percentile: Top 68%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimization of Gamma Image Quality Through Experimental Evaluation Using 3D-Printed Phantoms Across Energy Window Levels — Min-Gwan Lee, Chanrok Park, et al. · Bioengineering (2025) | TGRS Research Map | TGRS