Active Fast Neutron Multiplicity Counting with DT Neutron Generator

The active fast neutron multiplicity counting (AFNMC) apparatus was consisted of an array with 36 pieces of liquid scintillator detectors in three rings cylindrical layout, multi-modules 500M14bit digitizers based on PXIe platform, the DT neutron generator, shielding cone and mechanical structure. Its center cavity was 35 cm in radius and 50 cm in height for assaying the standard container of plutonium item. The DT neutron generator was the type of alpha-associated to make the neutron injecting into the assay area being tagged and located on the bottom of detector array. The shielding cone was fixed between the DT generator and the lower ring detector with a hole to let the tagged neutron injecting to the sample assay area. The alpha signal was used as gating signal when doing neutron mutiplicity analysis. The experiments were performed with iron, lead, HEU metal in standard container for technical verification. The SDT values from both conventional and gating FNMC were obtained for comparison. The experimental results indicated this method dramatically reduced the random or non-correlated neutron signal noise and substantially promoted the D and T values sensitivity when the alpha signal gating was enabled.

Authors

Institutions

Publication Details

Journal
EPJ Web of Conferences
Published
2025-01-01
DOI
https://doi.org/10.1051/epjconf/202533806010
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Active Fast Neutron Multiplicity Counting with DT Neutron Generator

Yu Jin, Jiansheng Li, Jian Tang, Xiaobo Liu
EPJ Web of Conferences
Radiation Detection and Scintillator Technologies
article

Active Fast Neutron Multiplicity Counting with DT Neutron Generator

Yu Jin, Jiansheng Li, Jian Tang, Xiaobo Liu
article en

Abstract

The active fast neutron multiplicity counting (AFNMC) apparatus was consisted of an array with 36 pieces of liquid scintillator detectors in three rings cylindrical layout, multi-modules 500M14bit digitizers based on PXIe platform, the DT neutron generator, shielding cone and mechanical structure. Its center cavity was 35 cm in radius and 50 cm in height for assaying the standard container of plutonium item. The DT neutron generator was the type of alpha-associated to make the neutron injecting into the assay area being tagged and located on the bottom of detector array. The shielding cone was fixed between the DT generator and the lower ring detector with a hole to let the tagged neutron injecting to the sample assay area. The alpha signal was used as gating signal when doing neutron mutiplicity analysis. The experiments were performed with iron, lead, HEU metal in standard container for technical verification. The SDT values from both conventional and gating FNMC were obtained for comparison. The experimental results indicated this method dramatically reduced the random or non-correlated neutron signal noise and substantially promoted the D and T values sensitivity when the alpha signal gating was enabled.

EPJ Web of ConferencesVol. 338
Institute of Nuclear Physics (UZ)
Openalex Percentile: Top 57%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Active Fast Neutron Multiplicity Counting with DT Neutron Generator — Yu Jin, Jiansheng Li, et al. · EPJ Web of Conferences (2025) | TGRS Research Map | TGRS