Towards Clinical Integration of a SPECT Detection Module for BNCT Dose Monitoring

Boron Neutron Capture Therapy (BNCT) is a targeted radiotherapy that requires precise dose monitoring to ensure effective treatment. We initially report experimental measurements performed with the BeNEdiCTE detector, designed for SPECT-based dose monitoring in BNCT. The detector is based on a co-doped LaBr 3 (Ce, Sr) monolithic crystal read out by Silicon Photomultipliers and compact electronics. Tomographic measurements were performed at the Laboratorio di Energia Nucleare Applicata in Pavia (Italy). Then, measurements with neutron conditions similar to those expected in clinical treatments were performed at the Nagoya University Acceleratordriven Neutron Source (Japan). The detector demonstrated the ability to detect the 478 keV gamma rays emitted during boron neutron capture reactions. Additionally, the detector successfully reconstructed 2D and 3D images of the boron distribution with sub-centimeter resolution. The measurements highlighted key areas for improvement to make the detector suitable for clinical use with patients, which will be presented in detail in this work. The boron present in the FR4 material used in the electronics boards was identified as a significant source of 478-keV gamma rays uncorrelated with the imaged object. To mitigate this, a new substrate material, RO3003, was tested, showing a substantial reduction in gamma rays emitted at 478 keV. Furthermore, the detector’s electronics were optimized to improve count-rate capability. This involved reducing the dead time from 5.4 µs to 2.1 µs and refining an energy thresholding mechanism to process only events around 478 keV. These improvements will enhance the detector’s performance, bringing it closer to clinical use with patients.

Authors

Institutions

Publication Details

Journal
EPJ Web of Conferences
Published
2025-01-01
DOI
https://doi.org/10.1051/epjconf/202533809001
Primary Topic
Boron Compounds in Chemistry
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards Clinical Integration of a SPECT Detection Module for BNCT Dose Monitoring

F. Ghisio, D. Mazzucconi, N. Protti, Yoko Ichikawa et al.
EPJ Web of Conferences
Boron Compounds in Chemistry
article

Towards Clinical Integration of a SPECT Detection Module for BNCT Dose Monitoring

F. Ghisio, D. Mazzucconi, N. Protti, Yoko Ichikawa, Marco Carminati, S. Altieri, S. Agosteo, G. Borghi, Lorenzo Santini, Koji Tsuchida, Tommaso Ferri, Carlo Ettore Fiorini, G. Iaselli, L. Grisoni, Anita Caracciolo
article en

Abstract

Boron Neutron Capture Therapy (BNCT) is a targeted radiotherapy that requires precise dose monitoring to ensure effective treatment. We initially report experimental measurements performed with the BeNEdiCTE detector, designed for SPECT-based dose monitoring in BNCT. The detector is based on a co-doped LaBr 3 (Ce, Sr) monolithic crystal read out by Silicon Photomultipliers and compact electronics. Tomographic measurements were performed at the Laboratorio di Energia Nucleare Applicata in Pavia (Italy). Then, measurements with neutron conditions similar to those expected in clinical treatments were performed at the Nagoya University Acceleratordriven Neutron Source (Japan). The detector demonstrated the ability to detect the 478 keV gamma rays emitted during boron neutron capture reactions. Additionally, the detector successfully reconstructed 2D and 3D images of the boron distribution with sub-centimeter resolution. The measurements highlighted key areas for improvement to make the detector suitable for clinical use with patients, which will be presented in detail in this work. The boron present in the FR4 material used in the electronics boards was identified as a significant source of 478-keV gamma rays uncorrelated with the imaged object. To mitigate this, a new substrate material, RO3003, was tested, showing a substantial reduction in gamma rays emitted at 478 keV. Furthermore, the detector’s electronics were optimized to improve count-rate capability. This involved reducing the dead time from 5.4 µs to 2.1 µs and refining an energy thresholding mechanism to process only events around 478 keV. These improvements will enhance the detector’s performance, bringing it closer to clinical use with patients.

EPJ Web of ConferencesVol. 338
Istituto Nazionale di Fisica Nucleare (IT), Politecnico di Torino (IT), University of Pavia (IT), Nagoya University (JP), Polytechnic University of Bari (IT), Politecnico di Milano (IT)
Ministero dell'Università e della Ricerca, Commissione Scientifica Nazionale 5, Instituto Nazionale di Fisica Nucleare
Openalex Percentile: Top 52%
Boron Compounds in Chemistry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.