Operational Correction for the Temperature Dependence of a Class of Hyperspectral Radiometers

Abstract The correction for temperature response of optical radiometers implies access to their working temperature (i.e., either the internal or ambient one with the radiometers in thermal equilibrium). With specific reference to a class of widely used hyperspectral radiometers lacking a thermistor to measure the internal temperature, this work investigated the potential for operational corrections relying on the ambient temperature derived from the radiometer dark digital counts. With the objective to keep within approximately 1% the uncertainty for radiometric corrections in the 400–800-nm spectral range, findings showed the applicability of the method for ambient temperatures higher than approximately 30°C. The alternative use of an ambient temperature proxy, determined from the air temperature incremented by a few degrees Celsius, was shown a valid solution to constrain the uncertainty of radiometric corrections to within 1% over the entire 0°–40°C interval.

Authors

Institutions

Publication Details

Journal
Journal of Atmospheric and Oceanic Technology
Published
2025-11-06
DOI
https://doi.org/10.1175/jtech-d-25-0049.1
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Operational Correction for the Temperature Dependence of a Class of Hyperspectral Radiometers

Giuseppe Zibordi, Marco Talone
Journal of Atmospheric and Oceanic Technology
Calibration and Measurement Techniques
article

Operational Correction for the Temperature Dependence of a Class of Hyperspectral Radiometers

Giuseppe Zibordi, Marco Talone
article en

Abstract

Abstract The correction for temperature response of optical radiometers implies access to their working temperature (i.e., either the internal or ambient one with the radiometers in thermal equilibrium). With specific reference to a class of widely used hyperspectral radiometers lacking a thermistor to measure the internal temperature, this work investigated the potential for operational corrections relying on the ambient temperature derived from the radiometer dark digital counts. With the objective to keep within approximately 1% the uncertainty for radiometric corrections in the 400–800-nm spectral range, findings showed the applicability of the method for ambient temperatures higher than approximately 30°C. The alternative use of an ambient temperature proxy, determined from the air temperature incremented by a few degrees Celsius, was shown a valid solution to constrain the uncertainty of radiometric corrections to within 1% over the entire 0°–40°C interval.

Journal of Atmospheric and Oceanic TechnologyVol. 42(12)
Goddard Space Flight Center (US), Southeastern Universities Research Association (US), Institut Català de Ciències del Clima (ES), National Aeronautics and Space Administration (US)
Openalex Percentile: Top 56%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Operational Correction for the Temperature Dependence of a Class of Hyperspectral Radiometers — Giuseppe Zibordi, Marco Talone · Journal of Atmospheric and Oceanic Technology (2025) | TGRS Research Map | TGRS