Experimental investigation on additively manufactured polymeric hybrid auxetic tubes for biomedical applications

Purpose Polymeric auxetic metamaterials have shown immense progress in their application as bioresorbable stents in the biomedical sector because of their superior mechanical and biocompatible properties. This paper aims to propose the implementation of novel hybrid auxetic structure in cylindrical stent prototypes. The proposed design is characterized by uniaxial tensile testing of standard specimens, axial and radial compression and three-point bending tests. The test outcomes made them suitable for stent fabrication in biomedical applications. Design/methodology/approach This research paper focuses on fabricating biodegradable hybrid auxetic tubes of transparent PLA and white PLA Pro+ by Fused Filament Fabrication (FFF). This novel polymeric hybrid auxetic tube (PHAT) design comprises re-entrant, hexagonal, meta-chiral auxetic unit cells. They are repeatedly arranged in a planar structure, rolled to form the cylindrical tube. Their deformation mechanisms are studied through experimental tests for stent applications. Findings The deformation pattern showcases half-wave and full-wave transformations on ligaments caused by anti-chiral and chiral circular nodes rotation, resulting in auxetic behavior due to Negative Poisson Ratio (NPR). The load displacement curves are plotted to evaluate axial, radial and bending stiffness as a measure of buckling resistance, crush resistance and bending flexibility to determine their suitability for stent applications. The axial foreshortening, radial recoil and dogboning rate are calculated to confirm their feasibility through the experimental test results. Originality/value The NPR values attained are −2.25 and −3.43 for transparent and white PLA Pro+ specimens, respectively. The axial stiffness of 166.18 N/mm and 105.96 N/mm, radial stiffness of 33.75 N/mm and 28.86 N/mm, bending stiffness value of 14.31 N.mm2 and 18.89 N.mm2 and bending flexibility of 69.93 × 10–3 1/N.mm2 and 52.94 × 10–3 1/N.mm2 are found for transparent PLA and white PLA Pro+, respectively. The foreshortening effects of 0.57% and 0.64%, radial recoil of 4.12% and 3.64% and dogboning effects of 9.67% and 10.56% are observed from experimental results.

Authors

Institutions

Publication Details

Journal
Rapid Prototyping Journal
Published
2025-11-06
DOI
https://doi.org/10.1108/rpj-05-2025-0202
Primary Topic
Cellular and Composite Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation on additively manufactured polymeric hybrid auxetic tubes for biomedical applications

Muthukannan Duraiselvam, R Dhiliepan
Rapid Prototyping Journal
Cellular and Composite Structures
article

Experimental investigation on additively manufactured polymeric hybrid auxetic tubes for biomedical applications

Muthukannan Duraiselvam, R Dhiliepan
article en

Abstract

Purpose Polymeric auxetic metamaterials have shown immense progress in their application as bioresorbable stents in the biomedical sector because of their superior mechanical and biocompatible properties. This paper aims to propose the implementation of novel hybrid auxetic structure in cylindrical stent prototypes. The proposed design is characterized by uniaxial tensile testing of standard specimens, axial and radial compression and three-point bending tests. The test outcomes made them suitable for stent fabrication in biomedical applications. Design/methodology/approach This research paper focuses on fabricating biodegradable hybrid auxetic tubes of transparent PLA and white PLA Pro+ by Fused Filament Fabrication (FFF). This novel polymeric hybrid auxetic tube (PHAT) design comprises re-entrant, hexagonal, meta-chiral auxetic unit cells. They are repeatedly arranged in a planar structure, rolled to form the cylindrical tube. Their deformation mechanisms are studied through experimental tests for stent applications. Findings The deformation pattern showcases half-wave and full-wave transformations on ligaments caused by anti-chiral and chiral circular nodes rotation, resulting in auxetic behavior due to Negative Poisson Ratio (NPR). The load displacement curves are plotted to evaluate axial, radial and bending stiffness as a measure of buckling resistance, crush resistance and bending flexibility to determine their suitability for stent applications. The axial foreshortening, radial recoil and dogboning rate are calculated to confirm their feasibility through the experimental test results. Originality/value The NPR values attained are −2.25 and −3.43 for transparent and white PLA Pro+ specimens, respectively. The axial stiffness of 166.18 N/mm and 105.96 N/mm, radial stiffness of 33.75 N/mm and 28.86 N/mm, bending stiffness value of 14.31 N.mm2 and 18.89 N.mm2 and bending flexibility of 69.93 × 10–3 1/N.mm2 and 52.94 × 10–3 1/N.mm2 are found for transparent PLA and white PLA Pro+, respectively. The foreshortening effects of 0.57% and 0.64%, radial recoil of 4.12% and 3.64% and dogboning effects of 9.67% and 10.56% are observed from experimental results.

Rapid Prototyping JournalVol. 32(3)
National Institute of Technology Tiruchirappalli (IN)
Openalex Percentile: Top 66%
Cellular and Composite Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.