Effect of implant tilt and trans-mucosal abutment angulation as influencing stress pattern: An FEA study
The effect of implant tilt and transmucosal abutment angulation on stress distribution around tilted dental implants in a simulated maxillary arch using Finite Element Analysis (FEA). Eight 3D models with varying implant tilts (17°, 25°, 30°, 35°) and abutment angulations (17°, 30°) were analyzed under a 200 N vertical load. Matched angulations (e.g., 17°/17°, 30°/30°) showed more uniform and favorable stress distribution. Angular mismatches greater than 5° significantly increase stress in abutments and crestal bone. Implant tilts beyond 30° combined with mismatched abutments may compromise biomechanical stability and prosthetic success.
Authors
- Bharti Dua
- Aman Verma (ORCID: https://orcid.org/0000-0001-7436-1325)
- Rajiv Gupta (ORCID: https://orcid.org/0000-0002-7196-0872)
- Akanksha Sharma (ORCID: https://orcid.org/0009-0005-0706-8950)
- T. D. Verma
- Akshay Bhargava (ORCID: https://orcid.org/0000-0003-2050-8875)
Institutions
- Santosh University (IN)
Publication Details
- Journal
- Bioinformation
- Published
- 2025-10-31
- DOI
- https://doi.org/10.6026/973206300213775
- Primary Topic
- Dental Implant Techniques and Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00