Evaluation of a new robotic spinal surgical system for K-wire placement characterized by tracker registration and lateral force sensing

Efficient registration and high-precision K-wire guidance are critical for the effective performance of spinal surgical robots. We therefore evaluate a new robotic system featuring optical tracker registration and a high-precision lateral force sensing system during K-wire placement. In this study, retrospectively collected clinical data were used to evaluate the technical efficacy and clinical utility of the system in spinal surgery. This was a retrospective study. Between December 2022 and April 2024, a total of 127 patients were enrolled and subjected to X-ray, CT, and MRI examinations. Among these patients, 67 were enrolled in the robot-assisted group, in which K-wires were implanted using a new spinal surgical robot. The remaining 60 patients were enrolled in the freehand group, where K-wires were implanted manually. The data collected included sex, age, body mass index, number of punctures (NOP), mean time required to insert a K-wire (MTRI K-wire), average blood loss per K-wire insertion (ABL K-wire), fluoroscopy count per K-wire (FC K-wire), puncture abduction angle (PAA), and K-wire in the pedicle (K-wire IP). Distance deviations and angle deviations were used as the primary parameters to evaluate the accuracy of the new spinal surgical robot. Compared with free-hand K-wire insertion, robot-assisted K-wire implantation results in fewer NOP, fewer MTRI K-wires, fewer ABL K-wires, fewer intraoperative FC K-wires, and a larger PAA. Compared with the free-hand group, the robot-assisted group demonstrated significantly smaller entry point deviation (0.98 ± 0.13 vs. 5.08 ± 1.17 mm, p < 0.001) and endpoint deviation (1.38 ± 0.20 vs. 5.52 ± 0.87 mm, p < 0.001). These results demonstrate superior targeting accuracy with robotic assistance relative to conventional freehand techniques. Our spinal surgical robot system demonstrates clinically reliable accuracy in K-wire placement while offering significant intraoperative advantages, including a streamlined procedural workflow, a reduced operation time, and minimal tissue trauma. These results demonstrate significant potential for both clinical implementation and further technological optimization. This trial was approved by the Ethics Committee of the Second Affiliated Hospital of Nanjing Medical University on February 21, 2023(2023XJ00401 retrospectively registered).

Authors

Institutions

Publication Details

Journal
Journal of Robotic Surgery
Published
2025-11-06
DOI
https://doi.org/10.1007/s11701-025-02950-w
Primary Topic
Cervical and Thoracic Myelopathy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a new robotic spinal surgical system for K-wire placement characterized by tracker registration and lateral force sensing

Jun Liu, Boyao Wang, Yancheng Zhu, Changzhi Du et al.
Journal of Robotic Surgery
Cervical and Thoracic Myelopathy
article

Evaluation of a new robotic spinal surgical system for K-wire placement characterized by tracker registration and lateral force sensing

Jun Liu, Boyao Wang, Yancheng Zhu, Changzhi Du, Yongkang Yang, Liang Li, Hailong Chen
article en

Abstract

Efficient registration and high-precision K-wire guidance are critical for the effective performance of spinal surgical robots. We therefore evaluate a new robotic system featuring optical tracker registration and a high-precision lateral force sensing system during K-wire placement. In this study, retrospectively collected clinical data were used to evaluate the technical efficacy and clinical utility of the system in spinal surgery. This was a retrospective study. Between December 2022 and April 2024, a total of 127 patients were enrolled and subjected to X-ray, CT, and MRI examinations. Among these patients, 67 were enrolled in the robot-assisted group, in which K-wires were implanted using a new spinal surgical robot. The remaining 60 patients were enrolled in the freehand group, where K-wires were implanted manually. The data collected included sex, age, body mass index, number of punctures (NOP), mean time required to insert a K-wire (MTRI K-wire), average blood loss per K-wire insertion (ABL K-wire), fluoroscopy count per K-wire (FC K-wire), puncture abduction angle (PAA), and K-wire in the pedicle (K-wire IP). Distance deviations and angle deviations were used as the primary parameters to evaluate the accuracy of the new spinal surgical robot. Compared with free-hand K-wire insertion, robot-assisted K-wire implantation results in fewer NOP, fewer MTRI K-wires, fewer ABL K-wires, fewer intraoperative FC K-wires, and a larger PAA. Compared with the free-hand group, the robot-assisted group demonstrated significantly smaller entry point deviation (0.98 ± 0.13 vs. 5.08 ± 1.17 mm, p < 0.001) and endpoint deviation (1.38 ± 0.20 vs. 5.52 ± 0.87 mm, p < 0.001). These results demonstrate superior targeting accuracy with robotic assistance relative to conventional freehand techniques. Our spinal surgical robot system demonstrates clinically reliable accuracy in K-wire placement while offering significant intraoperative advantages, including a streamlined procedural workflow, a reduced operation time, and minimal tissue trauma. These results demonstrate significant potential for both clinical implementation and further technological optimization. This trial was approved by the Ethics Committee of the Second Affiliated Hospital of Nanjing Medical University on February 21, 2023(2023XJ00401 retrospectively registered).

Journal of Robotic SurgeryVol. 19(1)
Second Affiliated Hospital of Nanjing Medical University (CN), Nanjing Medical University (CN)
Government of Jiangsu Province, Natural Science Foundation of Jiangsu Province, Nanjing Medical University
Openalex Percentile: Top 49%
Cervical and Thoracic Myelopathy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.