Fabrication and numerical analysis of non-metallic orthopedic prostheses using ultrasound techniques for reducing infection in sports-related injuries

Joint replacement has garnered considerable attention as a medical intervention for addressing sports-related joint injuries, offering the potential to restore sports activities and enhance quality of life. However, prioritizing safety measures and injury prevention during exercise is crucial. The increasing prevalence of infections in knee arthroplasty surgeries is a significant concern for both patients and surgeons, emphasizing the necessity for implants with proven efficacy against periprosthetic joint infections (PJI). In this study, two samples were prepared: sample 1 comprised pure copper nanoparticles, while sample 2 consisted of copper nanoparticles supplemented with titanium nanoparticles (TiNP) using the powder metallurgy (PM) technique. The copper prosthesis was characterized using X-ray diffraction (XRD), scanning electron microscope (SEM), and compressive strength tests. The biological behavior of the samples was evaluated in simulated body fluid (SBF) and phosphate buffer saline (PBS) over 3 months. The results demonstrated that the fabricated copper prosthesis exhibited a mesoporous microstructure, with a specific surface area ranging from 150 to 200 (cm 2 /g). The samples displayed porosity levels of 25 % to 32 %, with pore volumes ranging from 50 to 100 nm. The addition of TiNP to the copper nanoparticles reduced the specific surface area and pore volume of the prosthesis. Cell viability and electrical conductivity assessments revealed the formation of a thin apatite layer on the surface of the copper sample with added titanium nanoparticles. This study leverages the unique capabilities of ultrasound technology to fabricate and evaluate the performance of these novel prosthetic components. The inclusion of TiNP decreased the dissolution rate and increased apatite formation. Moreover, the mechanical properties of the prosthesis improved, and its biological behavior was enhanced, resulting in the development of a beam-shaped biological implant that was analytically analyzed. The addition of approximately 10 wt% TiNP was found to be effective in improving the mechanical and biological properties of the copper-titanium implant.

Authors

Institutions

Publication Details

Journal
Ain Shams Engineering Journal
Published
2025-11-06
DOI
https://doi.org/10.1016/j.asej.2025.103838
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication and numerical analysis of non-metallic orthopedic prostheses using ultrasound techniques for reducing infection in sports-related injuries

Dheyaa Jumaah Jasim, Shunxin Zhang, Soheil Salahshour, Ran Yin et al.
Ain Shams Engineering Journal
Orthopaedic implants and arthroplasty
article

Fabrication and numerical analysis of non-metallic orthopedic prostheses using ultrasound techniques for reducing infection in sports-related injuries

Dheyaa Jumaah Jasim, Shunxin Zhang, Soheil Salahshour, Ran Yin, S. Eftekharmanesh
article en

Abstract

Joint replacement has garnered considerable attention as a medical intervention for addressing sports-related joint injuries, offering the potential to restore sports activities and enhance quality of life. However, prioritizing safety measures and injury prevention during exercise is crucial. The increasing prevalence of infections in knee arthroplasty surgeries is a significant concern for both patients and surgeons, emphasizing the necessity for implants with proven efficacy against periprosthetic joint infections (PJI). In this study, two samples were prepared: sample 1 comprised pure copper nanoparticles, while sample 2 consisted of copper nanoparticles supplemented with titanium nanoparticles (TiNP) using the powder metallurgy (PM) technique. The copper prosthesis was characterized using X-ray diffraction (XRD), scanning electron microscope (SEM), and compressive strength tests. The biological behavior of the samples was evaluated in simulated body fluid (SBF) and phosphate buffer saline (PBS) over 3 months. The results demonstrated that the fabricated copper prosthesis exhibited a mesoporous microstructure, with a specific surface area ranging from 150 to 200 (cm 2 /g). The samples displayed porosity levels of 25 % to 32 %, with pore volumes ranging from 50 to 100 nm. The addition of TiNP to the copper nanoparticles reduced the specific surface area and pore volume of the prosthesis. Cell viability and electrical conductivity assessments revealed the formation of a thin apatite layer on the surface of the copper sample with added titanium nanoparticles. This study leverages the unique capabilities of ultrasound technology to fabricate and evaluate the performance of these novel prosthetic components. The inclusion of TiNP decreased the dissolution rate and increased apatite formation. Moreover, the mechanical properties of the prosthesis improved, and its biological behavior was enhanced, resulting in the development of a beam-shaped biological implant that was analytically analyzed. The addition of approximately 10 wt% TiNP was found to be effective in improving the mechanical and biological properties of the copper-titanium implant.

Ain Shams Engineering JournalVol. 17(1)
Piri Reis University (TR), Khazar University (AZ), Bahçeşehir University (TR), Hefei Normal University (CN), University of Al Maarif (IQ), Chinese PLA General Hospital (CN), Computing Center (RU), Okan University (TR)
Openalex Percentile: Top 49%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.