Self-Calibrating Position Measurements: Applied to Imperfect Hall Sensors

Linear Hall sensors are a cost-effective alternative to optical encoders for measuring the rotor positions of actuators, with the main challenge being that they exhibit position-dependent inaccuracies resulting from manufacturing tolerances. This paper develops a data-driven calibration procedure for linear analog Hall sensors that enables accurate online estimates of the rotor angle without requiring expensive external encoders. The approach combines closed-loop data collection with nonlinear identification to obtain an accurate model of the sensor inaccuracies, which is subsequently used for online compensation. Simulation results show that when the flux density model structure is known, measurement errors are reduced to the sensor noise floor, and experiments on an industrial setup demonstrate a factor of 2.6 reduction in the root-mean-square measurement error. These results confirm that Hall sensor inaccuracies can be calibrated even when no external encoder is available, improving their practical applicability.

Authors

Institutions

Publication Details

Journal
IFAC-PapersOnLine
Published
2025-01-01
DOI
https://doi.org/10.1016/j.ifacol.2025.10.143
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-Calibrating Position Measurements: Applied to Imperfect Hall Sensors

Gert Witvoet, Lennart Blanken, Tom Oomen, Max van Meer et al.
IFAC-PapersOnLine
Magnetic Field Sensors Techniques
article

Self-Calibrating Position Measurements: Applied to Imperfect Hall Sensors

Gert Witvoet, Lennart Blanken, Tom Oomen, Max van Meer, Koen Tiels, Enzo Evers, Marijn van Noije
article en

Abstract

Linear Hall sensors are a cost-effective alternative to optical encoders for measuring the rotor positions of actuators, with the main challenge being that they exhibit position-dependent inaccuracies resulting from manufacturing tolerances. This paper develops a data-driven calibration procedure for linear analog Hall sensors that enables accurate online estimates of the rotor angle without requiring expensive external encoders. The approach combines closed-loop data collection with nonlinear identification to obtain an accurate model of the sensor inaccuracies, which is subsequently used for online compensation. Simulation results show that when the flux density model structure is known, measurement errors are reduced to the sensor noise floor, and experiments on an industrial setup demonstrate a factor of 2.6 reduction in the root-mean-square measurement error. These results confirm that Hall sensor inaccuracies can be calibrated even when no external encoder is available, improving their practical applicability.

IFAC-PapersOnLineVol. 59(17)
Netherlands Organisation for Applied Scientific Research (NL), Prodrive Technologies (Netherlands) (NL), Eindhoven University of Technology (NL), Delft University of Technology (NL)
Openalex Percentile: Top 68%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.