Effective removal and concentration of perfluoroalkyl substances (PFAS) using asymmetric membrane capacitive deionization with stop–flow operation

• A novel ACDI system effectively adsorbed and concentrated short-chain PFAS. • Stop-flow operation significantly enhanced PFAS concentration factors • The effect of operational parameters was systematically investigated. • ACDI system demonstrated the treatment of PFAS under the simulated wastewater. The effective removal and concentration of perfluoroalkyl substances (PFAS) from aquatic environments has emerged as a critical challenge owing to their persistence, widespread occurrence, and potential human health risks. This study investigated the feasibility of using an asymmetric membrane capacitive deionization (ACDI) system for PFAS adsorption and concentration under various operational conditions. The results demonstrated that the ACDI system effectively adsorbed short-chain PFAS, even at low concentrations. Additionally, by employing a stop-flow operation during the desorption phase, the concentration factor was enhanced by 1.4 to 2.8 times compared to that achieved under a continuous-flow operation. The effects of key operational parameters, including initial concentration, applied voltage, flow rate, and desorption time, were systematically evaluated, in which the maximum concentration factor also reached 6.15 times. The performance of the system was further assessed using single-component, multi-component, and simulated semiconductor wastewater solutions containing various types of PFAS. Notably, even in simulated semiconductor wastewater containing high levels of competing ions and organic matter, the ACDI system maintained superior adsorption and concentration performance for short-chain PFAS, particularly trifluoroacetic acid (TFA). Overall, this study provides valuable insights into the applicability and operational factors associated with implementing ACDI systems for PFAS treatment scenarios, highlighting their effectiveness in the removal and concentration of short-chain PFAS.

Authors

Institutions

Publication Details

Journal
Water Research X
Published
2025-11-06
DOI
https://doi.org/10.1016/j.wroa.2025.100444
Citations
1
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effective removal and concentration of perfluoroalkyl substances (PFAS) using asymmetric membrane capacitive deionization with stop–flow operation

Eunji J. Lee, Yunho Lee, Hongsik Yoon, Taijin Min et al.
1 citations
Water Research X
Per- and polyfluoroalkyl substances research
0.86
article

Effective removal and concentration of perfluoroalkyl substances (PFAS) using asymmetric membrane capacitive deionization with stop–flow operation

Eunji J. Lee, Yunho Lee, Hongsik Yoon, Taijin Min, SeongBeom Jeon, Nguyen Cong Hau
article en
1 citations

Abstract

• A novel ACDI system effectively adsorbed and concentrated short-chain PFAS. • Stop-flow operation significantly enhanced PFAS concentration factors • The effect of operational parameters was systematically investigated. • ACDI system demonstrated the treatment of PFAS under the simulated wastewater. The effective removal and concentration of perfluoroalkyl substances (PFAS) from aquatic environments has emerged as a critical challenge owing to their persistence, widespread occurrence, and potential human health risks. This study investigated the feasibility of using an asymmetric membrane capacitive deionization (ACDI) system for PFAS adsorption and concentration under various operational conditions. The results demonstrated that the ACDI system effectively adsorbed short-chain PFAS, even at low concentrations. Additionally, by employing a stop-flow operation during the desorption phase, the concentration factor was enhanced by 1.4 to 2.8 times compared to that achieved under a continuous-flow operation. The effects of key operational parameters, including initial concentration, applied voltage, flow rate, and desorption time, were systematically evaluated, in which the maximum concentration factor also reached 6.15 times. The performance of the system was further assessed using single-component, multi-component, and simulated semiconductor wastewater solutions containing various types of PFAS. Notably, even in simulated semiconductor wastewater containing high levels of competing ions and organic matter, the ACDI system maintained superior adsorption and concentration performance for short-chain PFAS, particularly trifluoroacetic acid (TFA). Overall, this study provides valuable insights into the applicability and operational factors associated with implementing ACDI systems for PFAS treatment scenarios, highlighting their effectiveness in the removal and concentration of short-chain PFAS.

Water Research XVol. 29
Gwangju Institute of Science and Technology (KR), Korea Institute of Machinery & Materials (KR)
Openalex Percentile: Top 22%
Per- and polyfluoroalkyl substances research
0.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.