Application of a g-C <sub>3</sub> N <sub>4</sub> @nZVI/CNTs Modified Carbon Paste Electrode for Uric Acid Detection in Spiked Urine Samples

A carbon paste electrode (CPE) based on a g-C 3 N 4 @nZVI/CNT nanocomposite was fabricated via chemical reduction and subsequently evaluated towards electrochemical detection of uric acid (UA) via differential pulse voltammetry (DPV). During synthesis, graphitic carbon nitride (g-C 3 N 4 ) serves as a durable substrate with extensive surface area promoting the homogeneous distribution of nano zero-valent iron (nZVI) particles. Carbon nanotubes (CNTs) were incorporated into the composite to enhance electrical conductivity and mechanical stability. The subsequent nanocomposite was characterized by scanning electron microscopy and energy-dispersive X-ray spectroscopy, confirming the successful integration of g-C 3 N 4 , nZVI, and CNTs with well-dispersed iron nanoparticles on the g-C 3 N 4 matrix. The resulting g-C 3 N 4 @nZVI/CNT-modified CPE demonstrated superior electrochemical sensitivity toward UA as evidenced by a pronounced increase in peak current during DPV analysis compared to bare and individually modified electrodes. Under optimized conditions, the sensor exhibited a linear response of 2.0–100.0 μM and detection limit of 1.7 μM. The electrode maintained high selectivity in the presence of common interferants with good repeatability and long-term operational stability. These findings highlight the synergistic interaction among g-C 3 N 4 , nZVI, and CNTs in boosting electron transfer and catalytic activity, making this composite a promising, cost-effective, and scalable solution for sensitive UA detection in clinical diagnostics and environmental monitoring.

Authors

Institutions

Publication Details

Journal
ECS Sensors Plus
Published
2025-11-05
DOI
https://doi.org/10.1149/2754-2726/ae1bb7
Citations
5
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
3.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of a g-C 3 N 4 @nZVI/CNTs Modified Carbon Paste Electrode for Uric Acid Detection in Spiked Urine Samples

Ola G. Hussein, Jeffrey G. Bell, Amr M. Mahmoud, Maria Osama Mekhail et al.
5 citations
ECS Sensors Plus
Electrochemical sensors and biosensors
3.65
article

Application of a g-C 3 N 4 @nZVI/CNTs Modified Carbon Paste Electrode for Uric Acid Detection in Spiked Urine Samples

Ola G. Hussein, Jeffrey G. Bell, Amr M. Mahmoud, Maria Osama Mekhail, Taher Taha Zaki, Aya Ahmed
article en
5 citations

Abstract

A carbon paste electrode (CPE) based on a g-C 3 N 4 @nZVI/CNT nanocomposite was fabricated via chemical reduction and subsequently evaluated towards electrochemical detection of uric acid (UA) via differential pulse voltammetry (DPV). During synthesis, graphitic carbon nitride (g-C 3 N 4 ) serves as a durable substrate with extensive surface area promoting the homogeneous distribution of nano zero-valent iron (nZVI) particles. Carbon nanotubes (CNTs) were incorporated into the composite to enhance electrical conductivity and mechanical stability. The subsequent nanocomposite was characterized by scanning electron microscopy and energy-dispersive X-ray spectroscopy, confirming the successful integration of g-C 3 N 4 , nZVI, and CNTs with well-dispersed iron nanoparticles on the g-C 3 N 4 matrix. The resulting g-C 3 N 4 @nZVI/CNT-modified CPE demonstrated superior electrochemical sensitivity toward UA as evidenced by a pronounced increase in peak current during DPV analysis compared to bare and individually modified electrodes. Under optimized conditions, the sensor exhibited a linear response of 2.0–100.0 μM and detection limit of 1.7 μM. The electrode maintained high selectivity in the presence of common interferants with good repeatability and long-term operational stability. These findings highlight the synergistic interaction among g-C 3 N 4 , nZVI, and CNTs in boosting electron transfer and catalytic activity, making this composite a promising, cost-effective, and scalable solution for sensitive UA detection in clinical diagnostics and environmental monitoring.

ECS Sensors PlusVol. 4(4)
Cairo University (EG), Future University in Egypt (EG), Washington State University (US)
Openalex Percentile: Top 6%
Electrochemical sensors and biosensors
3.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.