Thermal–mechanical investigation of steel tanks for molten salt thermal energy storage

Molten salts play an important role in the renewable energy transition, serving as a thermal storage medium for concentrated solar power. This study presents a numerical investigation into the thermal and mechanical performance of a steel tank, of commercial size and setup, for molten salt storage. A 2D axisymmetric sequential thermal-stress model is developed. Input parameters are validated from the data of the Solar Two and Andasol plants. Thermal-mechanical stress analysis is performed considering the yield criterion and directionality. A sensitivity analysis is performed for inventory level, thermal gradient, friction coefficient, inventory temperature, and foundation stiffness. The transient operating condition with cyclic thermal and mechanical loads is simulated. Elastic–plastic analysis is performed to predict the damage location and residual stress during an operation cycle. From the stress analysis, mechanical stress as high as 268 MPa develops at the tank floor edge, which reduces to 197 MPa with the salt thermal load. At the center, a maximum stress of 157 MPa is generated, but only due to thermal loads. The temperature gradient and higher friction between the tank floor and foundation exacerbate the stress levels. These stresses exceed the yield strength limit of steel. During a cyclic transient operation, radial stress of 260 MPa develops at the floor edge where the elastic–plastic damage occurs. Residual stress of 82 MPa and 35 MPa is generated in radial and circumferential directions. The floor deforms plastically every operation cycle and can eventually crack. This study offers a comprehensive analysis of the tank’s thermal-mechanical behavior and offers insights to mitigate potential failures and optimize design. • Developed and validated a thermal-stress model of a commercial-size molten salt tank. • Analyzed stress on the tank floor, considering the yield criterion and directionality. • Studied stress on the tank floor under varying physical and operational parameters. • Simulated the tank’s transient operating condition. • Predicted elastic–plastic damage location and residual stress during a cyclic operation.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2025-11-05
DOI
https://doi.org/10.1016/j.applthermaleng.2025.128930
Citations
3
Primary Topic
Phase Change Materials Research
Type
article
Field-Weighted Citation Impact
2.14
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal–mechanical investigation of steel tanks for molten salt thermal energy storage

Huu‐Tai Thai, Santosh Mishra, Tuan Ngoc Nguyen, Tuan Ngo
3 citations
Applied Thermal Engineering
Phase Change Materials Research
2.14
article

Thermal–mechanical investigation of steel tanks for molten salt thermal energy storage

Huu‐Tai Thai, Santosh Mishra, Tuan Ngoc Nguyen, Tuan Ngo
article en
3 citations

Abstract

Molten salts play an important role in the renewable energy transition, serving as a thermal storage medium for concentrated solar power. This study presents a numerical investigation into the thermal and mechanical performance of a steel tank, of commercial size and setup, for molten salt storage. A 2D axisymmetric sequential thermal-stress model is developed. Input parameters are validated from the data of the Solar Two and Andasol plants. Thermal-mechanical stress analysis is performed considering the yield criterion and directionality. A sensitivity analysis is performed for inventory level, thermal gradient, friction coefficient, inventory temperature, and foundation stiffness. The transient operating condition with cyclic thermal and mechanical loads is simulated. Elastic–plastic analysis is performed to predict the damage location and residual stress during an operation cycle. From the stress analysis, mechanical stress as high as 268 MPa develops at the tank floor edge, which reduces to 197 MPa with the salt thermal load. At the center, a maximum stress of 157 MPa is generated, but only due to thermal loads. The temperature gradient and higher friction between the tank floor and foundation exacerbate the stress levels. These stresses exceed the yield strength limit of steel. During a cyclic transient operation, radial stress of 260 MPa develops at the floor edge where the elastic–plastic damage occurs. Residual stress of 82 MPa and 35 MPa is generated in radial and circumferential directions. The floor deforms plastically every operation cycle and can eventually crack. This study offers a comprehensive analysis of the tank’s thermal-mechanical behavior and offers insights to mitigate potential failures and optimize design. • Developed and validated a thermal-stress model of a commercial-size molten salt tank. • Analyzed stress on the tank floor, considering the yield criterion and directionality. • Studied stress on the tank floor under varying physical and operational parameters. • Simulated the tank’s transient operating condition. • Predicted elastic–plastic damage location and residual stress during a cyclic operation.

Applied Thermal EngineeringVol. 283
The University of Melbourne (AU)
Openalex Percentile: Top 12%
Phase Change Materials Research
2.14
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.