Interior Decorative VOCs Elevate T Cell‐Mediated Obstructive Lung Disease Risks via Osteogenesis‐Driven Lymphoid‐Biased Hematopoiesis

Volatile organic compounds (VOCs) emitted from interior decorations are suggested to pose substantial respiratory hazards as they disturb the immune response in the lung. Despite this, the characteristics and mechanisms underlying immune cell responses to real-world VOC mixtures, rather than previously individual or dominant VOC species, remain poorly understood. Employing a whole-body inhalation exposure model, we reveal that interior decorative VOCs alter pulmonary immune cell profiles with a persistent increase in alveolar T cells. This sustained elevation results from intensified lymphoid-biased hematopoiesis in the bone marrow (BM) rather than in situ lung, which is followed by thymic maturation and subsequent recruitment to lung tissues. The ex vivo biosensor and antibody neutralization assays clarify that VOCs-induced lymphoid-biased hematopoiesis is primarily driven by osteogenic differentiation within the BM niche, a process further regulated by interleukin-6 (IL-6) and interleukin-17A (IL-17A). Moreover, the cohort study associates VOCs-expanded lymphocytes with increased risks of obstructive lung diseases, where exposed individuals show elevated IL-6 and IL-17A levels, correlating with VOC concentrations and lymphocyte proportions. These findings highlight compelling indicators (i.e., T cells) and potential interventions (i.e., IL-6 and IL-17A) for evaluating and mitigating VOC-associated respiratory risks.

Authors

Institutions

Publication Details

Journal
Advanced Science
Published
2025-11-05
DOI
https://doi.org/10.1002/advs.202512663
Citations
1
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
1.20

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interior Decorative VOCs Elevate T Cell‐Mediated Obstructive Lung Disease Risks via Osteogenesis‐Driven Lymphoid‐Biased Hematopoiesis

Miao Gan, Qingping Liu, D Li, Guangbo Qu et al.
1 citations
Advanced Science
Indoor Air Quality and Microbial Exposure
1.20
article

Interior Decorative VOCs Elevate T Cell‐Mediated Obstructive Lung Disease Risks via Osteogenesis‐Driven Lymphoid‐Biased Hematopoiesis

Miao Gan, Qingping Liu, D Li, Guangbo Qu, Jingxu Zhang, Hongyan Yu, Xiaoting Jin, Ruonan Pan, Rong Zhang, Yuxin Zheng, Yidi Chen, Zengqiang Kou
article en
1 citations

Abstract

Volatile organic compounds (VOCs) emitted from interior decorations are suggested to pose substantial respiratory hazards as they disturb the immune response in the lung. Despite this, the characteristics and mechanisms underlying immune cell responses to real-world VOC mixtures, rather than previously individual or dominant VOC species, remain poorly understood. Employing a whole-body inhalation exposure model, we reveal that interior decorative VOCs alter pulmonary immune cell profiles with a persistent increase in alveolar T cells. This sustained elevation results from intensified lymphoid-biased hematopoiesis in the bone marrow (BM) rather than in situ lung, which is followed by thymic maturation and subsequent recruitment to lung tissues. The ex vivo biosensor and antibody neutralization assays clarify that VOCs-induced lymphoid-biased hematopoiesis is primarily driven by osteogenic differentiation within the BM niche, a process further regulated by interleukin-6 (IL-6) and interleukin-17A (IL-17A). Moreover, the cohort study associates VOCs-expanded lymphocytes with increased risks of obstructive lung diseases, where exposed individuals show elevated IL-6 and IL-17A levels, correlating with VOC concentrations and lymphocyte proportions. These findings highlight compelling indicators (i.e., T cells) and potential interventions (i.e., IL-6 and IL-17A) for evaluating and mitigating VOC-associated respiratory risks.

Advanced ScienceVol. 13(4)
Qingdao University (CN), Hebei Medical University (CN), Chinese Academy of Sciences (CN), Qingdao Mental Health Center (CN), Institute for Advanced Study (DE), Research Center for Eco-Environmental Sciences (CN), Zaozhuang University (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China, Servier, Natural Science Foundation of Qingdao
Openalex Percentile: Top 17%
Indoor Air Quality and Microbial Exposure
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.