Biomechanical Evaluation of Implant-Supported Three-Unit Bridge Designs and Retention Types in the Atrophic Posterior Maxilla Using Finite Element Analysis

Background and Objectives: This study aimed to evaluate the biomechanical behavior of three-unit implant-supported prostheses with different bridge configurations (mesial cantilever, distal cantilever, and pontic) and two types of retention in the atrophic posterior maxilla, through three-dimensional finite element analysis (3D FEA). The focus was on stress distribution in short implants used in pontic and mesial cantilever designs. Materials and Methods: Six 3D finite element models were developed to represent various prosthetic designs and retention mechanisms in a maxillary segment including the first premolar, second premolar, and first molar regions. Type III bone with 8 mm vertical height simulated an atrophic maxilla. Standard implants were placed in premolar areas and short implants in molar regions. A 100 N oblique load at 45° was applied to each unit to simulate masticatory function. Stress distribution was assessed using von Mises and principal stress criteria. Results: The highest implant and crown stress occurred in the cement-retained distal cantilever (100.14 MPa and 329.95 MPa, respectively), while the lowest values were found in the screw-retained pontic model (44.74 MPa and 81.23 MPa). Mesial cantilevers showed intermediate stress levels. Screw-retained designs generally generated lower stresses within implants than cement-retained ones. In cortical bone, stress ranged from 10.25 MPa in the cement-retained distal cantilever to 4.22 MPa in the screw-retained pontic, while trabecular bone showed maximum stress of 1.69 MPa and 0.82 MPa, respectively. Conclusions: Prosthetic design and retention type significantly influenced biomechanical performance. Screw-retained pontic prostheses with short implants in the molar region provided the most favorable stress distribution. When cantilevers are required, mesial extensions are biomechanically more advantageous than distal ones. Short implants can thus be safely used in the posterior maxilla when accompanied by proper prosthetic design and retention type.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-11-05
DOI
https://doi.org/10.3390/app152111793
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Evaluation of Implant-Supported Three-Unit Bridge Designs and Retention Types in the Atrophic Posterior Maxilla Using Finite Element Analysis

Yeliz Hayran, Arzu Yüksel Baysal
Applied Sciences
Dental Implant Techniques and Outcomes
article

Biomechanical Evaluation of Implant-Supported Three-Unit Bridge Designs and Retention Types in the Atrophic Posterior Maxilla Using Finite Element Analysis

Yeliz Hayran, Arzu Yüksel Baysal
article en

Abstract

Background and Objectives: This study aimed to evaluate the biomechanical behavior of three-unit implant-supported prostheses with different bridge configurations (mesial cantilever, distal cantilever, and pontic) and two types of retention in the atrophic posterior maxilla, through three-dimensional finite element analysis (3D FEA). The focus was on stress distribution in short implants used in pontic and mesial cantilever designs. Materials and Methods: Six 3D finite element models were developed to represent various prosthetic designs and retention mechanisms in a maxillary segment including the first premolar, second premolar, and first molar regions. Type III bone with 8 mm vertical height simulated an atrophic maxilla. Standard implants were placed in premolar areas and short implants in molar regions. A 100 N oblique load at 45° was applied to each unit to simulate masticatory function. Stress distribution was assessed using von Mises and principal stress criteria. Results: The highest implant and crown stress occurred in the cement-retained distal cantilever (100.14 MPa and 329.95 MPa, respectively), while the lowest values were found in the screw-retained pontic model (44.74 MPa and 81.23 MPa). Mesial cantilevers showed intermediate stress levels. Screw-retained designs generally generated lower stresses within implants than cement-retained ones. In cortical bone, stress ranged from 10.25 MPa in the cement-retained distal cantilever to 4.22 MPa in the screw-retained pontic, while trabecular bone showed maximum stress of 1.69 MPa and 0.82 MPa, respectively. Conclusions: Prosthetic design and retention type significantly influenced biomechanical performance. Screw-retained pontic prostheses with short implants in the molar region provided the most favorable stress distribution. When cantilevers are required, mesial extensions are biomechanically more advantageous than distal ones. Short implants can thus be safely used in the posterior maxilla when accompanied by proper prosthetic design and retention type.

Applied SciencesVol. 15(21)
Bursa Uludağ Üni̇versi̇tesi̇ (TR), Tokat Gaziosmanpaşa Üniversitesi (TR)
Openalex Percentile: Top 53%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.