Hydrogel nanocomposite-based breathable non-adhesive coating for oxygen sensing film used within extracorporeal perfusion system

Real-time, quantitative biosensing within extracorporeal perfusion (ECP) and extracorporeal membrane oxygenation (ECMO) systems is key to advancing this life-support technology beyond the hospital setting to emergency care. Measuring and monitoring [Formula: see text] concentration in blood is particularly important but is challenged by fouling of the sensor. Here we report a novel hydrogel nanocomposite coating, composed of polysulfobetaine, polyethylene glycol, and titanium dioxide nanoparticles, for a metalloporphyrin-based oxygen sensor. The hydrogel nanocomposite exhibits minimal cytotoxicity and hemolytic effects (< 5%), as well as non-adhesive and non-coagulant properties in contact with lung endothelial cells and human plasma, ensuring its compatibility with blood-contacting applications. The incorporation of titanium dioxide nanoparticles provides a white, light-scattering surface to improve sensor signal reflection, enhances the hydrogel's mechanical strength (storage modulus > 1000 Pa), and maintains a pore area on the order of μm<sup>2</sup> to facilitate efficient fluid and gas diffusion to the oxygen sensing film. Notably, the hydrogel nanocomposite enables rapid, accurate (within 2 mmHg of the analytical reference), and continuous monitoring of oxygen partial pressures ([Formula: see text]) in PBS and blood for over 90 minutes within a miniaturized flow cell integrated in an extracorporeal perfusion-mimicking system. To our knowledge, this is the first report of a blood-compatible biomaterial that enables real-time [Formula: see text] monitoring in a lightweight, compact sensor, suitable for integration into ECP and ECMO circuits.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-05
DOI
https://doi.org/10.1038/s41598-025-22520-2
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hydrogel nanocomposite-based breathable non-adhesive coating for oxygen sensing film used within extracorporeal perfusion system

Mark W. Grinstaff, Badri Parshad, Shatruhan Singh Rajput, Rachel S. Knipe et al.
1 citations
Scientific Reports
Analytical Chemistry and Sensors
0.74
article

Hydrogel nanocomposite-based breathable non-adhesive coating for oxygen sensing film used within extracorporeal perfusion system

Mark W. Grinstaff, Badri Parshad, Shatruhan Singh Rajput, Rachel S. Knipe, Juan Pedro Cascales, Emmanouil Roussakis, Xingyu Hu, Anna Wiatrowski, Conor L. Evans, Fei Peng, Tyler McPartland, Trọng Hung Nguyen, Julia B. Slade, Isabelle Nagle
article en
1 citations

Abstract

Real-time, quantitative biosensing within extracorporeal perfusion (ECP) and extracorporeal membrane oxygenation (ECMO) systems is key to advancing this life-support technology beyond the hospital setting to emergency care. Measuring and monitoring [Formula: see text] concentration in blood is particularly important but is challenged by fouling of the sensor. Here we report a novel hydrogel nanocomposite coating, composed of polysulfobetaine, polyethylene glycol, and titanium dioxide nanoparticles, for a metalloporphyrin-based oxygen sensor. The hydrogel nanocomposite exhibits minimal cytotoxicity and hemolytic effects (< 5%), as well as non-adhesive and non-coagulant properties in contact with lung endothelial cells and human plasma, ensuring its compatibility with blood-contacting applications. The incorporation of titanium dioxide nanoparticles provides a white, light-scattering surface to improve sensor signal reflection, enhances the hydrogel's mechanical strength (storage modulus > 1000 Pa), and maintains a pore area on the order of μm<sup>2</sup> to facilitate efficient fluid and gas diffusion to the oxygen sensing film. Notably, the hydrogel nanocomposite enables rapid, accurate (within 2 mmHg of the analytical reference), and continuous monitoring of oxygen partial pressures ([Formula: see text]) in PBS and blood for over 90 minutes within a miniaturized flow cell integrated in an extracorporeal perfusion-mimicking system. To our knowledge, this is the first report of a blood-compatible biomaterial that enables real-time [Formula: see text] monitoring in a lightweight, compact sensor, suitable for integration into ECP and ECMO circuits.

Scientific ReportsVol. 15(1)
Boston University (US), Universidad Complutense de Madrid (ES), Harvard University (US), University of Cambridge (GB), Massachusetts General Hospital (US)
U.S. Department of Defense, Comunidad de Madrid, Air Force Office of Scientific Research
Openalex Percentile: Top 25%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.