Experimental research on the fire resistance of columns in container-style steel modular buildings
This study investigates the fire resistance of columns in container-style steel modular buildings through fire tests. Three individual columns and one combined column were tested to evaluate the fire resistance performance of various protective measures: fire-resistant coatings, calcium silicate boards, and rock wool sandwich panels. The combined column protected by 75 mm rock wool sandwich panels achieved a fire resistance limit of 102.1 min. The study concludes that rock wool sandwich panels are a feasible, economical fire protection solution for such columns. The required thickness of rock wool for different fire resistance limits was calculated, providing valuable design insights for container-style steel modular buildings.
Authors
- Jintao Duan (ORCID: https://orcid.org/0000-0002-0493-755X)
- Jianyong Liu (ORCID: https://orcid.org/0000-0003-4865-1585)
- Shijie Gao (ORCID: https://orcid.org/0000-0003-4717-4094)
- Hao Wu (ORCID: https://orcid.org/0000-0002-8629-2053)
- Wei Ji
Institutions
- Bureau Veritas (France) (FR)
- Shenzhen Metro (China) (CN)
- Guangzhou Panyu Polytechnic (CN)
- Guangzhou Building Materials Institute (CN)
Publication Details
- Journal
- Scientific Reports
- Published
- 2025-11-05
- DOI
- https://doi.org/10.1038/s41598-025-22642-7
- Primary Topic
- Fire effects on concrete materials
- Type
- article
- Field-Weighted Citation Impact
- 0.00