Advances and Challenges in LSD Detection: Analytical Techniques, Matrix Selection, and Validation Gaps in Forensic Toxicology

Lysergic acid diethylamide (LSD) remains a significant forensic and public health concern due to its widespread abuse and association with drug-facilitated crimes. Detecting LSD and its analogs in biological specimens, particularly postmortem matrices, presents analytical challenges stemming from its low dosage, rapid metabolism, and structural similarities to novel lysergamides. This review critically examines trends in validated analytical methods for LSD detection in forensic toxicology. A systematic review of literature from 1978 to 2025 was conducted using databases, such as PubMed, ScienceDirect, and Google Scholar. The analysis focused on reported methodologies for LSD and its metabolites across various matrices, including blood, urine, hair, oral fluid, and vitreous humor. Extraction techniques (LLE, SPE, DLLME) and analytical platforms (GC-MS/MS, LC-MS/MS, CE-MS) were compared, with emphasis on validation parameters, such as sensitivity, specificity, recovery, LOD, LOQ, matrix effects, and stability. The review identifies LC-MS/MS as the most sensitive and widely validated technique; however, discrepancies remain in matrix-specific validations and stability assessments. Challenges include the lack of certified reference materials for LSD analogs, matrix-dependent degradation, and limited methods for emerging sample types, such as dried blood spots (DBS). Few studies fully comply with modern forensic validation guidelines, limiting the reproducibility and admissibility of results in legal settings. This review highlights critical gaps in current forensic LSD detection protocols and underscores the need for standardized, validated methods applicable to diverse matrices. Future research should prioritize the development of rapid, eco-friendly, high-throughput methods capable of detecting LSD and its analogs at ultra-trace levels.

Authors

Institutions

Publication Details

Journal
Critical Reviews in Analytical Chemistry
Published
2025-11-04
DOI
https://doi.org/10.1080/10408347.2025.2578622
Primary Topic
Psychedelics and Drug Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advances and Challenges in LSD Detection: Analytical Techniques, Matrix Selection, and Validation Gaps in Forensic Toxicology

Diksha Thakur, Neeti Prakash Dubey, Rajvinder Singh, Ajay Kumar
Critical Reviews in Analytical Chemistry
Psychedelics and Drug Studies
article

Advances and Challenges in LSD Detection: Analytical Techniques, Matrix Selection, and Validation Gaps in Forensic Toxicology

Diksha Thakur, Neeti Prakash Dubey, Rajvinder Singh, Ajay Kumar
article en

Abstract

Lysergic acid diethylamide (LSD) remains a significant forensic and public health concern due to its widespread abuse and association with drug-facilitated crimes. Detecting LSD and its analogs in biological specimens, particularly postmortem matrices, presents analytical challenges stemming from its low dosage, rapid metabolism, and structural similarities to novel lysergamides. This review critically examines trends in validated analytical methods for LSD detection in forensic toxicology. A systematic review of literature from 1978 to 2025 was conducted using databases, such as PubMed, ScienceDirect, and Google Scholar. The analysis focused on reported methodologies for LSD and its metabolites across various matrices, including blood, urine, hair, oral fluid, and vitreous humor. Extraction techniques (LLE, SPE, DLLME) and analytical platforms (GC-MS/MS, LC-MS/MS, CE-MS) were compared, with emphasis on validation parameters, such as sensitivity, specificity, recovery, LOD, LOQ, matrix effects, and stability. The review identifies LC-MS/MS as the most sensitive and widely validated technique; however, discrepancies remain in matrix-specific validations and stability assessments. Challenges include the lack of certified reference materials for LSD analogs, matrix-dependent degradation, and limited methods for emerging sample types, such as dried blood spots (DBS). Few studies fully comply with modern forensic validation guidelines, limiting the reproducibility and admissibility of results in legal settings. This review highlights critical gaps in current forensic LSD detection protocols and underscores the need for standardized, validated methods applicable to diverse matrices. Future research should prioritize the development of rapid, eco-friendly, high-throughput methods capable of detecting LSD and its analogs at ultra-trace levels.

Critical Reviews in Analytical Chemistry
Central Forensic Science Laboratory (IN), Association for Symbolic Logic (US), Maine Farmland Trust (US), Institute of Forensic Science (CN), Maharshi Dayanand University (IN)
Openalex Percentile: Top 55%
Psychedelics and Drug Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.