Intraoperative precision of 25-gauge beveled-tip versus 23-gauge flat-tip probes in day surgery vitrectomy for proliferative diabetic retinopathy: a comparative cohort study

To compare the intraoperative performance and safety of the 10k cuts-per-minute (cpm)/25-gauge (G) beveled-tip probe (BTP) versus the 5k-cpm/23-G flat-tip probe (FTP) in microincision vitrectomy surgery (MIVS) for proliferative diabetic retinopathy (PDR). This comparative interventional cohort study enrolled 173 eyes of 156 consecutive patients with PDR. Eyes underwent MIVS by a single surgeon from April 2022 to June 2023, utilizing either the 10k/25-G BTP (study group) or the 5k/23-G FTP (control group). All patients completed 3-month protocolized follow-up; 72.8% (126 eyes) had extended observational tracking to 6 months. Intraoperative parameters (instrument exchange, endodiathermy application), surgical times, and postoperative outcomes were analyzed. Main Outcome Measures: Rate of instrument exchange, number of endodiathermy applications, and operative time. Baseline demographics and operative characteristics were comparable between groups. Total operative time (63.30 ± 18.38 vs. 59.84 ± 19.28 min, P = 0.14) and vitrectomy time (36.55 ± 15.54 vs. 35.59 ± 16.59, P = 0.67) did not differ significantly. The 25-G BTP group demonstrated a 41% reduction in instrument exchanges (1.31 ± 2.02 vs. 2.22 ± 2.71, P = 0.003) and required 58% fewer endodiathermy applications (2.28 ± 3.33 vs. 5.49 ± 6.49 sites, P < 0.0001). Sutureless sclerotomy rates were higher in the 23-G group (83.9% vs. 23.3%, P < 0.0001). Postoperative best-corrected visual acuity improvement, complication rates, and intraocular pressure control were equivalent between groups at 3 months and 6 months. While both systems achieve equivalent visual and anatomical outcomes in PDR surgery, the 10k/25-G BTP system facilitates a novel “Trim and Excision” Technique, enabling more precise dissection of fibrovascular tissue. This technique translates to superior intraoperative efficiency and safety, significantly reducing instrument dependence and iatrogenic hemorrhage without compromising surgical speed or postoperative recovery. This trial is registered with the Chinese Clinical Trial Registry ( http://www.chictr.org.cn , registration number ChiCTR2300067743). Date of registration: 2023-01-20.

Authors

Institutions

Publication Details

Journal
International Journal of Retina and Vitreous
Published
2025-11-05
DOI
https://doi.org/10.1186/s40942-025-00746-6
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intraoperative precision of 25-gauge beveled-tip versus 23-gauge flat-tip probes in day surgery vitrectomy for proliferative diabetic retinopathy: a comparative cohort study

Xin Luo, Yanchun Zhang, Yuxin He, Ziwei Kang et al.
International Journal of Retina and Vitreous
Retinal and Macular Surgery
article

Intraoperative precision of 25-gauge beveled-tip versus 23-gauge flat-tip probes in day surgery vitrectomy for proliferative diabetic retinopathy: a comparative cohort study

Xin Luo, Yanchun Zhang, Yuxin He, Ziwei Kang, Jiamin Zheng, D. S. Xue
article en

Abstract

To compare the intraoperative performance and safety of the 10k cuts-per-minute (cpm)/25-gauge (G) beveled-tip probe (BTP) versus the 5k-cpm/23-G flat-tip probe (FTP) in microincision vitrectomy surgery (MIVS) for proliferative diabetic retinopathy (PDR). This comparative interventional cohort study enrolled 173 eyes of 156 consecutive patients with PDR. Eyes underwent MIVS by a single surgeon from April 2022 to June 2023, utilizing either the 10k/25-G BTP (study group) or the 5k/23-G FTP (control group). All patients completed 3-month protocolized follow-up; 72.8% (126 eyes) had extended observational tracking to 6 months. Intraoperative parameters (instrument exchange, endodiathermy application), surgical times, and postoperative outcomes were analyzed. Main Outcome Measures: Rate of instrument exchange, number of endodiathermy applications, and operative time. Baseline demographics and operative characteristics were comparable between groups. Total operative time (63.30 ± 18.38 vs. 59.84 ± 19.28 min, P = 0.14) and vitrectomy time (36.55 ± 15.54 vs. 35.59 ± 16.59, P = 0.67) did not differ significantly. The 25-G BTP group demonstrated a 41% reduction in instrument exchanges (1.31 ± 2.02 vs. 2.22 ± 2.71, P = 0.003) and required 58% fewer endodiathermy applications (2.28 ± 3.33 vs. 5.49 ± 6.49 sites, P < 0.0001). Sutureless sclerotomy rates were higher in the 23-G group (83.9% vs. 23.3%, P < 0.0001). Postoperative best-corrected visual acuity improvement, complication rates, and intraocular pressure control were equivalent between groups at 3 months and 6 months. While both systems achieve equivalent visual and anatomical outcomes in PDR surgery, the 10k/25-G BTP system facilitates a novel “Trim and Excision” Technique, enabling more precise dissection of fibrovascular tissue. This technique translates to superior intraoperative efficiency and safety, significantly reducing instrument dependence and iatrogenic hemorrhage without compromising surgical speed or postoperative recovery. This trial is registered with the Chinese Clinical Trial Registry ( http://www.chictr.org.cn , registration number ChiCTR2300067743). Date of registration: 2023-01-20.

International Journal of Retina and VitreousVol. 11(1)
Shaanxi Provincial People's Hospital (CN)
Openalex Percentile: Top 53%
Retinal and Macular Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.