Physician-Modified Custom Made Endograft Adding an Outer Branch to Correct a Fenestration Offset

Urgent setting may demand further modifications of readily available CMD, including the incorporation of branches in fenestrated stent grafts, in order to accommodate in patient's anatomy. Future standardization of the modification techniques may further expand their utilization.Clinical ImpactThis case introduces a physician-modified endograft technique incorporating an outer branch into pre-existing fenestrated custom-made device (CMD) for urgent complex aortic aneurysm repair. Using an available CMD instead of creating a new PMEG reduces preparation time and procedural complexity while maintaining technical success and target vessel patency. This practical, repoducible approach broadens the applicability of fenestrated technology in urgent settings lacking suitable off-the-shelf options.

Authors

Institutions

Publication Details

Journal
Journal of Endovascular Therapy
Published
2025-11-05
DOI
https://doi.org/10.1177/15266028251384208
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physician-Modified Custom Made Endograft Adding an Outer Branch to Correct a Fenestration Offset

José I. Torrealba, Tilo Kölbel, Giuseppe Panuccio, Lorenzo Torri et al.
Journal of Endovascular Therapy
Aortic aneurysm repair treatments
article

Physician-Modified Custom Made Endograft Adding an Outer Branch to Correct a Fenestration Offset

José I. Torrealba, Tilo Kölbel, Giuseppe Panuccio, Lorenzo Torri, Petroula Nana
article en

Abstract

Urgent setting may demand further modifications of readily available CMD, including the incorporation of branches in fenestrated stent grafts, in order to accommodate in patient's anatomy. Future standardization of the modification techniques may further expand their utilization.Clinical ImpactThis case introduces a physician-modified endograft technique incorporating an outer branch into pre-existing fenestrated custom-made device (CMD) for urgent complex aortic aneurysm repair. Using an available CMD instead of creating a new PMEG reduces preparation time and procedural complexity while maintaining technical success and target vessel patency. This practical, repoducible approach broadens the applicability of fenestrated technology in urgent settings lacking suitable off-the-shelf options.

Journal of Endovascular Therapy
Universität Hamburg (DE), University Medical Center Hamburg-Eppendorf (DE), German Centre for Cardiovascular Research (DE)
Openalex Percentile: Top 53%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Physician-Modified Custom Made Endograft Adding an Outer Branch to Correct a Fenestration Offset — José I. Torrealba, Tilo Kölbel, et al. · Journal of Endovascular Therapy (2025) | TGRS Research Map | TGRS