Early Outcome after Aortic Valve Replacement with a Sutureless Bioprosthesis

Background: Aortic stenosis is one of the most prevalent valvular disorders. In people experiencing symptoms, the life expectancy decreases if the condition is not addressed. The only effective treatment for significant aortic lesions is valve replacement. This study aimed at reporting the early clinical outcomes of aortic valve replacement with Perceval sutureless bioprosthesis. Methods: The study involved 50 patients aged 21 to 82 years, comprising both genders, who were indicated for aortic valve replacement with or without additional cardiac procedures and consented to participate. Patients were included based on their desire for or indication of receiving a tissue valve. Results: Dedicated Aortic cross clamp time was 43.90±7.53 minutes, and Effective orifice Area at discharge was 1.51±0.12. Hemodynamics assessment at discharge showed good function of all implanted valves with low trans-valvular pressure gradients (mean, 11.14±4.19 mmHg and peak, 20.72±7.31mm Hg) and low incidence of paravalvular leakage. We had one In-hospital mortality (2%). Up to six months after surgery, survivors demonstrated a positive clinical outcome, and the valve prosthesis maintained stable hemodynamic functionality. One patient (2%) had a Paravalvular leak progressing over time and required reoperation. Permanent pacemaker incidence was 6%. Conclusions: Prosthetic hemodynamic performance was satisfactory, early results showed a high rate of successful implantation, and times for aortic cross-clamp and cardiopulmonary bypass were shorter than those for traditional aortic valve replacement, according to published data. Mortality and morbidity rates were also low.

Authors

Institutions

Publication Details

Journal
Al-Azhar International Medical Journal /Al-Azhar International Medical Journal
Published
2025-06-30
DOI
https://doi.org/10.21608/aimj.2025.446611
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Early Outcome after Aortic Valve Replacement with a Sutureless Bioprosthesis

El Husseiny El Husseiny Gamil, A. A. Sallam, Al Sayed Salem, Hatem Mohammed Abu-El Abu- Elhasan
Al-Azhar International Medical Journal /Al-Azhar International Medical Journal
Cardiac Valve Diseases and Treatments
article

Early Outcome after Aortic Valve Replacement with a Sutureless Bioprosthesis

El Husseiny El Husseiny Gamil, A. A. Sallam, Al Sayed Salem, Hatem Mohammed Abu-El Abu- Elhasan
article en

Abstract

Background: Aortic stenosis is one of the most prevalent valvular disorders. In people experiencing symptoms, the life expectancy decreases if the condition is not addressed. The only effective treatment for significant aortic lesions is valve replacement. This study aimed at reporting the early clinical outcomes of aortic valve replacement with Perceval sutureless bioprosthesis. Methods: The study involved 50 patients aged 21 to 82 years, comprising both genders, who were indicated for aortic valve replacement with or without additional cardiac procedures and consented to participate. Patients were included based on their desire for or indication of receiving a tissue valve. Results: Dedicated Aortic cross clamp time was 43.90±7.53 minutes, and Effective orifice Area at discharge was 1.51±0.12. Hemodynamics assessment at discharge showed good function of all implanted valves with low trans-valvular pressure gradients (mean, 11.14±4.19 mmHg and peak, 20.72±7.31mm Hg) and low incidence of paravalvular leakage. We had one In-hospital mortality (2%). Up to six months after surgery, survivors demonstrated a positive clinical outcome, and the valve prosthesis maintained stable hemodynamic functionality. One patient (2%) had a Paravalvular leak progressing over time and required reoperation. Permanent pacemaker incidence was 6%. Conclusions: Prosthetic hemodynamic performance was satisfactory, early results showed a high rate of successful implantation, and times for aortic cross-clamp and cardiopulmonary bypass were shorter than those for traditional aortic valve replacement, according to published data. Mortality and morbidity rates were also low.

Al-Azhar International Medical Journal /Al-Azhar International Medical JournalVol. 2025(6)
Al-Azhar University (EG), Birmingham Children's Hospital (GB), National Heart Institute (EG)
Openalex Percentile: Top 50%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Early Outcome after Aortic Valve Replacement with a Sutureless Bioprosthesis — El Husseiny El Husseiny Gamil, A. A. Sallam, et al. · Al-Azhar International Medical Journal /Al-Azhar International Medical Journal (2025) | TGRS Research Map | TGRS