Tensile behavior and microstructural evolution of rubber-modified ECC under thermo-mechanical loadings

Engineered Cementitious Composites (ECC), known for their high ductility and crack control capacity, have been rarely studied under in-situ elevated temperature conditions. Most existing studies evaluate ECC after high-temperature exposure, overlooking its real-time mechanical response and microstructural evolution under thermo-mechanical coupling. In this study, rubber particles were used to replace quartz powder at different ratios (0%, 10%, 20%, and 30%) to produce rubber-modified ECC (R-ECC). Quasi-static uniaxial tensile tests were conducted under various elevated temperatures (25℃, 70℃, 100℃, and 150℃). The effects of temperature and rubber content on mass loss, pore structure, cracking behavior, and tensile stress–strain response were systematically investigated. Results showed that increasing temperature significantly reduced both the initial cracking strength and tensile strength of R-ECC. However, in the sub-high temperature regime (70-100℃), R-ECC exhibited enhanced ductility, with the highest ultimate tensile strain observed at 100℃. This enhancement was attributed to moderate fiber softening, weakened matrix strength, and improved fiber pull-out behavior. In contrast, at 150℃, fiber melting and interfacial degradation sharply reduced tensile performance. Microstructural analysis demonstrated that internal changes including increased porosity, weakened rubber-matrix interface, and damaged PE fibers collectively contributed to the modified tensile behavior under coupled thermal–mechanical conditions. These findings provide new insights into the practical design and application of rubber-modified ECC in structures exposed to sub-high temperature service environments.

Authors

Publication Details

Journal
Lifeline Emergency and Safety
Published
2025-11-05
DOI
https://doi.org/10.26599/lles.2025.9660011
Primary Topic
Innovative concrete reinforcement materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tensile behavior and microstructural evolution of rubber-modified ECC under thermo-mechanical loadings

Jia-Xiang Lin, Ge Zhang, Jun‐Jie Zeng, Xiaofeng Chen et al.
Lifeline Emergency and Safety
Innovative concrete reinforcement materials
article

Tensile behavior and microstructural evolution of rubber-modified ECC under thermo-mechanical loadings

Jia-Xiang Lin, Ge Zhang, Jun‐Jie Zeng, Xiaofeng Chen, Shuo Wang, Heng-Liang Liu, Beixin Xie, Wei Deng
article en

Abstract

Engineered Cementitious Composites (ECC), known for their high ductility and crack control capacity, have been rarely studied under in-situ elevated temperature conditions. Most existing studies evaluate ECC after high-temperature exposure, overlooking its real-time mechanical response and microstructural evolution under thermo-mechanical coupling. In this study, rubber particles were used to replace quartz powder at different ratios (0%, 10%, 20%, and 30%) to produce rubber-modified ECC (R-ECC). Quasi-static uniaxial tensile tests were conducted under various elevated temperatures (25℃, 70℃, 100℃, and 150℃). The effects of temperature and rubber content on mass loss, pore structure, cracking behavior, and tensile stress–strain response were systematically investigated. Results showed that increasing temperature significantly reduced both the initial cracking strength and tensile strength of R-ECC. However, in the sub-high temperature regime (70-100℃), R-ECC exhibited enhanced ductility, with the highest ultimate tensile strain observed at 100℃. This enhancement was attributed to moderate fiber softening, weakened matrix strength, and improved fiber pull-out behavior. In contrast, at 150℃, fiber melting and interfacial degradation sharply reduced tensile performance. Microstructural analysis demonstrated that internal changes including increased porosity, weakened rubber-matrix interface, and damaged PE fibers collectively contributed to the modified tensile behavior under coupled thermal–mechanical conditions. These findings provide new insights into the practical design and application of rubber-modified ECC in structures exposed to sub-high temperature service environments.

Lifeline Emergency and SafetyVol. 1(1)
Openalex Percentile: Top 66%
Innovative concrete reinforcement materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.