Simulation-driven dual-band Graphene–Silver terahertz metasurface biosensor integrated with machine learning for mode-resolved hemoglobin detection

Accurate hemoglobin measurement is essential for diagnosing hematological disorders and monitoring cardiovascular health. This study introduces a terahertz metasurface biosensor combined with machine learning algorithms for rapid and non-invasive hemoglobin detection in clinical settings. The metasurface exhibits dual-band resonance in two terahertz regions, achieving a sensitivity of 450 GHz/RIU within a refractive index range of 1.34–1.43 RIU, with corresponding frequency shifts of 40 GHz and 30 GHz. Machine learning models, including Random Forest, Support Vector Machines, and Neural Networks, enhance the sensor’s analytical capability. Across four clinical categories—normal, mild anemia, moderate anemia, and severe anemia—the models attain 96.5 percent classification accuracy, with recall and precision scores above 0.94. Ensemble learning reduces the root mean square error to 0.28 g/dL, while denoising methods increase the signal-to-noise ratio by 16.3 dB. The biosensor supports real-time analysis, requires minimal sample volume, and eliminates complex preparation, making it suitable for continuous hemoglobin monitoring and cardiovascular health management. • Dual-band THz metasurface achieves 450 GHz/RIU sensitivity for hemoglobin detection. • ML integration enables 96.5% classification accuracy across anemia severity categories. • Ensemble learning lowers RMSE to 0.28 g/dL for precise hemoglobin quantification. • ML-driven denoising enhances spectral SNR by 16.3 dB for robust signal analysis. • Real-time, low-volume, preparation-free sensing supports proactive cardiovascular care.

Authors

Institutions

Publication Details

Journal
Sensors International
Published
2025-11-05
DOI
https://doi.org/10.1016/j.sintl.2025.100357
Primary Topic
Terahertz technology and applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation-driven dual-band Graphene–Silver terahertz metasurface biosensor integrated with machine learning for mode-resolved hemoglobin detection

Gunasekaran Thangavel, Manjunathan Alagarsamy, V. Selvaraj, K. Manivannan et al.
Sensors International
Terahertz technology and applications
article

Simulation-driven dual-band Graphene–Silver terahertz metasurface biosensor integrated with machine learning for mode-resolved hemoglobin detection

Gunasekaran Thangavel, Manjunathan Alagarsamy, V. Selvaraj, K. Manivannan, V. Joseph Michael Jerard, A. Sasikumar
article en

Abstract

Accurate hemoglobin measurement is essential for diagnosing hematological disorders and monitoring cardiovascular health. This study introduces a terahertz metasurface biosensor combined with machine learning algorithms for rapid and non-invasive hemoglobin detection in clinical settings. The metasurface exhibits dual-band resonance in two terahertz regions, achieving a sensitivity of 450 GHz/RIU within a refractive index range of 1.34–1.43 RIU, with corresponding frequency shifts of 40 GHz and 30 GHz. Machine learning models, including Random Forest, Support Vector Machines, and Neural Networks, enhance the sensor’s analytical capability. Across four clinical categories—normal, mild anemia, moderate anemia, and severe anemia—the models attain 96.5 percent classification accuracy, with recall and precision scores above 0.94. Ensemble learning reduces the root mean square error to 0.28 g/dL, while denoising methods increase the signal-to-noise ratio by 16.3 dB. The biosensor supports real-time analysis, requires minimal sample volume, and eliminates complex preparation, making it suitable for continuous hemoglobin monitoring and cardiovascular health management. • Dual-band THz metasurface achieves 450 GHz/RIU sensitivity for hemoglobin detection. • ML integration enables 96.5% classification accuracy across anemia severity categories. • Ensemble learning lowers RMSE to 0.28 g/dL for precise hemoglobin quantification. • ML-driven denoising enhances spectral SNR by 16.3 dB for robust signal analysis. • Real-time, low-volume, preparation-free sensing supports proactive cardiovascular care.

Sensors InternationalVol. 7
Jain University (IN), Presidency University (IN), SRM Dental College (IN), Muscat College (OM)
Openalex Percentile: Top 68%
Terahertz technology and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.