Zero-shot multi-modal large language models v.s. supervised deep learning: A comparative analysis on CT-based intracranial hemorrhage subtyping

Comparison of responses from six multi-modal large language models on a random case, which illustrates a fracture in the patient’s left skull due to trauma, with subdural hemorrhage (SDH) evident in the left hemisphere and intraparenchymal hemorrhage (IPH) in the right hemisphere. • Multi-modal large language models (MLLMs) show potential in intracranial hemorrhage (ICH) diagnosis and treatment with visual and interactive capabilities. • Proprietary and open-source MLLMs still underperform in ICH binary/subtype classification compared to trained deep networks. • MLLMs require fine-tuning for improved ICH subtyping and related tasks. Objective: Accurate identification of intracranial hemorrhage (ICH) subtypes on non-contrast CT is crucial for prognosis and treatment but remains challenging due to low contrast and blurred boundaries. This study evaluates the zero-shot performance of multi-modal large language models (MLLMs) versus traditional deep learning in ICH detection and subtyping. Methods: Using 192 NCCT volumes from the RSNA dataset, we compared MLLMs (GPT-4o, Gemini 2.0 Flash, Claude 3.5 Sonnet V2) with deep learning models (ResNet50, Vision Transformer). MLLMs were prompted for ICH presence, subtype, localization, and volume estimation. Results: Traditional deep learning models outperformed MLLMs in both ICH detection and subtyping. For subtyping, MLLMs showed lower accuracy, with Gemini 2.0 Flash achieving a macro-averaged precision of 0.41 and F1 score of 0.31. Conclusions: While MLLMs offer enhanced interpretability through language-based interaction, their accuracy in ICH subtyping remains inferior to deep learning networks. Further optimization is needed to improve their utility in three-dimensional medical imaging.

Authors

Institutions

Publication Details

Journal
Brain Hemorrhages
Published
2025-11-05
DOI
https://doi.org/10.1016/j.hest.2025.10.004
Citations
2
Primary Topic
Intracerebral and Subarachnoid Hemorrhage Research
Type
article
Field-Weighted Citation Impact
2.78
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Zero-shot multi-modal large language models v.s. supervised deep learning: A comparative analysis on CT-based intracranial hemorrhage subtyping

Meng Cai, Yue Zeng, Chao Pan, Yinuo Wang et al.
2 citations
Brain Hemorrhages
Intracerebral and Subarachnoid Hemorrhage Research
2.78
article

Zero-shot multi-modal large language models v.s. supervised deep learning: A comparative analysis on CT-based intracranial hemorrhage subtyping

Meng Cai, Yue Zeng, Chao Pan, Yinuo Wang, Zhouping Tang, Kai Chen
article en
2 citations

Abstract

Comparison of responses from six multi-modal large language models on a random case, which illustrates a fracture in the patient’s left skull due to trauma, with subdural hemorrhage (SDH) evident in the left hemisphere and intraparenchymal hemorrhage (IPH) in the right hemisphere. • Multi-modal large language models (MLLMs) show potential in intracranial hemorrhage (ICH) diagnosis and treatment with visual and interactive capabilities. • Proprietary and open-source MLLMs still underperform in ICH binary/subtype classification compared to trained deep networks. • MLLMs require fine-tuning for improved ICH subtyping and related tasks. Objective: Accurate identification of intracranial hemorrhage (ICH) subtypes on non-contrast CT is crucial for prognosis and treatment but remains challenging due to low contrast and blurred boundaries. This study evaluates the zero-shot performance of multi-modal large language models (MLLMs) versus traditional deep learning in ICH detection and subtyping. Methods: Using 192 NCCT volumes from the RSNA dataset, we compared MLLMs (GPT-4o, Gemini 2.0 Flash, Claude 3.5 Sonnet V2) with deep learning models (ResNet50, Vision Transformer). MLLMs were prompted for ICH presence, subtype, localization, and volume estimation. Results: Traditional deep learning models outperformed MLLMs in both ICH detection and subtyping. For subtyping, MLLMs showed lower accuracy, with Gemini 2.0 Flash achieving a macro-averaged precision of 0.41 and F1 score of 0.31. Conclusions: While MLLMs offer enhanced interpretability through language-based interaction, their accuracy in ICH subtyping remains inferior to deep learning networks. Further optimization is needed to improve their utility in three-dimensional medical imaging.

Brain HemorrhagesVol. 6(6)
Tongji Hospital (CN), Huazhong University of Science and Technology (CN), Beihang University (CN)
Openalex Percentile: Top 8%
Intracerebral and Subarachnoid Hemorrhage Research
2.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.