Sub-second response algorithm for wearable glucose sensors: normalized slope-based calibration and microvolumes differential compensation measurements
Traditional methods of blood glucose monitoring are invasive and can cause anxiety, pain and infection, resulting in poor patient compliance. Sweat-based glucose sensing has emerged as a promising non-invasive alternative, but the significantly lower glucose concentrations (10 to 100 times lower than in blood) pose a challenge for sensor sensitivity and operation. Here, we present different measurement protocols for enzymatic electrochemical glucose sensors with enhanced sensitivity and sub-second response calibration algorithm. The resulting amperometric response accurately reflects glucose concentration, demonstrating the sensor's potential for non-invasive monitoring of glucose in sweat. To enhance the reliability of the measurements and mitigate the variability among sensors arising from differences in sweat composition and secretion, a post-measurement protocol was developed. This protocol exploits a Response Correction Factor (RCF) calculated from the specific sensitivity of each sensor. This approach compensates for variability among different sensors reducing the standard deviation, thereby improving calibration accuracy (R 2 =0.995 vs. R 2 =0.822 without correction) allowing the prevention of phenomena related to enzyme inactivation or allogeneic reactions that may affect individual sensors in Continuous Glucose Monitoring (CGM) systems. An in-depth analysis was also conducted using sample microvolumes (20 μL), the typical amount of sweat available in wearable devices, to study thin-layer chronoamperometry response. To enhance the linearity of the sensor response, a differential compensation algorithm based on the slope of the response curve was adopted, employing a sensor without enzyme as a reference. This measurement method enhanced the dynamic range of slope values from 0.0085 μA/s to 0.0125 μA/s. The experimental results identified in a reliable way three operational regions: physiological (60-110 μM), warning values (110-160 μM) and alert/risk (>160 μM). The proposed strategies increase the robustness and applicability of sweat-based glucose monitoring for real-world applications.
Authors
- L. Velardi (ORCID: https://orcid.org/0000-0003-4518-9217)
- Laura Blasi (ORCID: https://orcid.org/0000-0002-9702-0272)
- Luca Francioso (ORCID: https://orcid.org/0000-0002-4500-0421)
- Elisa Sciurti (ORCID: https://orcid.org/0000-0003-1914-0153)
- Flavio Casino
- Daniele Bellisario (ORCID: https://orcid.org/0009-0000-2015-1971)
- Vanessa Esposito (ORCID: https://orcid.org/0009-0000-3719-0731)
- A. Calogiuri
Institutions
- Institute for Microelectronics and Microsystems (IT)
Publication Details
- Journal
- Measurement Sensors
- Published
- 2025-11-05
- DOI
- https://doi.org/10.1016/j.measen.2025.101977
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 0.00