Analysis of Active and Passive Thermal Management System for Cooling of Lithium‐Ion Battery Pack

Heat dissipation of lithium‐ion cells during its operation is critical for its performance. This study investigates the thermal behavior of a Li‐ion battery module (7.8 Ah, 11.1 V) under varying discharge rates (C‐rate) (0.91 to 1.45C) using experimental and numerical methods. Under natural convection at 1.45C C‐rate and 27°C ambient temperature, the module reaches 55.2°C, exceeding safe operational limits. Forced convection (FC) with inlet velocities of 0.4 and 0.7 ms −1 reduces the temperature to 40.8 and 37.7°C, respectively, though it causes temperature nonuniformity. To address these limitations, passive cooling with phase change material (PCM) was explored. PCM lowered the maximum temperature to 39.8°C with improved temperature uniformity (Δ T = 3.1°C). Further enhancement using expanded graphite increased PCM's thermal conductivity, maintaining low and uniform temperatures. Numerical simulations, validated against experimental results, were conducted to analyze heat transfer mechanisms under extreme C‐rates up to 5C and hot ambient temperatures up to 45°C. The findings demonstrate that while FC effectively cools lithium‐ion modules, it may reduce cell performance due to uneven temperature distribution. In contrast, PCM‐based passive cooling offers better temperature uniformity, though it is limited by low thermal conductivity, which can be mitigated by incorporating EG.

Authors

Institutions

Publication Details

Journal
Energy Technology
Published
2025-11-04
DOI
https://doi.org/10.1002/ente.202501326
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Active and Passive Thermal Management System for Cooling of Lithium‐Ion Battery Pack

M.S. Abhishek, Sreedhar Madichetty, Bhaskar Tamma, Manish Kumar Agrawal et al.
Energy Technology
Advanced Battery Technologies Research
article

Analysis of Active and Passive Thermal Management System for Cooling of Lithium‐Ion Battery Pack

M.S. Abhishek, Sreedhar Madichetty, Bhaskar Tamma, Manish Kumar Agrawal, Manoj Desu, Srihari Bommanchu
article en

Abstract

Heat dissipation of lithium‐ion cells during its operation is critical for its performance. This study investigates the thermal behavior of a Li‐ion battery module (7.8 Ah, 11.1 V) under varying discharge rates (C‐rate) (0.91 to 1.45C) using experimental and numerical methods. Under natural convection at 1.45C C‐rate and 27°C ambient temperature, the module reaches 55.2°C, exceeding safe operational limits. Forced convection (FC) with inlet velocities of 0.4 and 0.7 ms −1 reduces the temperature to 40.8 and 37.7°C, respectively, though it causes temperature nonuniformity. To address these limitations, passive cooling with phase change material (PCM) was explored. PCM lowered the maximum temperature to 39.8°C with improved temperature uniformity (Δ T = 3.1°C). Further enhancement using expanded graphite increased PCM's thermal conductivity, maintaining low and uniform temperatures. Numerical simulations, validated against experimental results, were conducted to analyze heat transfer mechanisms under extreme C‐rates up to 5C and hot ambient temperatures up to 45°C. The findings demonstrate that while FC effectively cools lithium‐ion modules, it may reduce cell performance due to uneven temperature distribution. In contrast, PCM‐based passive cooling offers better temperature uniformity, though it is limited by low thermal conductivity, which can be mitigated by incorporating EG.

Energy TechnologyVol. 14(1)
Mahindra Group (India) (IN)
Openalex Percentile: Top 64%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Active and Passive Thermal Management System for Cooling of Lithium‐Ion Battery Pack — M.S. Abhishek, Sreedhar Madichetty, et al. · Energy Technology (2025) | TGRS Research Map | TGRS