A hemoglobin concentration dataset derived from triple-wavelength photoplethysmography for machine learning applications

The commonly used method for measuring Hemoglobin (Hb) concentration involves invasive blood sampling, which has drawbacks such as discomfort and pain. To address these limitations, photoplethysmography (PPG) has emerged as a promising non-invasive alternative. PPG device is a non-invasive optical device used to detect blood volume changes within microvascular tissue beds. This device offers the capability to measure hemoglobin levels without the need for invasive procedures. In this article, the dataset consists of PPG signal, Hb value, age, and gender. The PPG signal was measured by a MAXM86161 module sensor that emitted triple-wavelength light (green, red and infrared). Data was collected from 52 subjects (60 % female, 40 % male), with Hb values ranging from 12 to 20 g/dL for males and 8-18 g/dL for females. Acquisition occurred from April to May 2025 at West Java, Indonesia. The public dataset on Mendeley Data includes raw PPG signals, filtered outputs, and peak detection results for each subject. This resource is valuable for researchers advancing non-invasive Hb measurement based on machine learning.

Authors

Institutions

Publication Details

Journal
Data in Brief
Published
2025-11-05
DOI
https://doi.org/10.1016/j.dib.2025.112241
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A hemoglobin concentration dataset derived from triple-wavelength photoplethysmography for machine learning applications

Tomy Abuzairi, Diva Bintang Maharani
Data in Brief
Non-Invasive Vital Sign Monitoring
article

A hemoglobin concentration dataset derived from triple-wavelength photoplethysmography for machine learning applications

Tomy Abuzairi, Diva Bintang Maharani
article en

Abstract

The commonly used method for measuring Hemoglobin (Hb) concentration involves invasive blood sampling, which has drawbacks such as discomfort and pain. To address these limitations, photoplethysmography (PPG) has emerged as a promising non-invasive alternative. PPG device is a non-invasive optical device used to detect blood volume changes within microvascular tissue beds. This device offers the capability to measure hemoglobin levels without the need for invasive procedures. In this article, the dataset consists of PPG signal, Hb value, age, and gender. The PPG signal was measured by a MAXM86161 module sensor that emitted triple-wavelength light (green, red and infrared). Data was collected from 52 subjects (60 % female, 40 % male), with Hb values ranging from 12 to 20 g/dL for males and 8-18 g/dL for females. Acquisition occurred from April to May 2025 at West Java, Indonesia. The public dataset on Mendeley Data includes raw PPG signals, filtered outputs, and peak detection results for each subject. This resource is valuable for researchers advancing non-invasive Hb measurement based on machine learning.

Data in BriefVol. 63
University of Indonesia (ID)
Openalex Percentile: Top 68%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A hemoglobin concentration dataset derived from triple-wavelength photoplethysmography for machine learning applications — Tomy Abuzairi, Diva Bintang Maharani · Data in Brief (2025) | TGRS Research Map | TGRS