The integration of phase change energy storage with cooling systems not only reduces the need for mechanical refrigeration in data centers (DCs), but also significantly enhances energy efficiency. However, research on the application location of phase change energy storage systems in DCs and the structural characteristics of system devices are limited. This paper combines the features of shell-and-tube and plate heat exchangers to design the porous phase change plate (PPCP) for use in DCs air conditioning systems and explores its cooling performance through experiments. The study employed single-factor and orthogonal experiments to analyze the effects of inlet air temperature, air velocity, aperture size and placement distance of the PPCP on the performance of the phase change heat device (PCHD) and evaluated the auxiliary effects of the device. The results indicate that: (1) The PCHD can reduce the air temperature by an average of 1.59 to 3.90 °C within 8 h. (2) The aperture size of the PPCP significantly affects the cooling performance of PCHD: a reduction in the PPCP aperture size by 2 cm results in an 8 % to 11 % enhancement in cooling performance. (3) In a comprehensive analysis of multiple factors, the primary and secondary factors of the PPCP are inlet air temperature > air velocity > aperture size > placement distance. (4) During high-temperature loads, the PCHD can assist in reducing mechanical energy consumption by up to 63 %. • Proposed to add a phase change energy storage functional section in air conditioning systems of data centers • Designed porous phase change plates for air conditioning system in data centers • Explored the influencing factors and laws of phase change heat device (PCHD) • PCHD can reduce temperature by 1.59–3.9 °C in 8 h.

Authors

Institutions

Publication Details

Journal
Journal of Energy Storage
Published
2025-11-05
DOI
https://doi.org/10.1016/j.est.2025.119290
Primary Topic
Phase Change Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on thermal performance of porous phase change plates assisted air conditioning system in data centers

Hongwei Wu, Ruiyong Mao, Zujing Zhang, Xing Liang et al.
Journal of Energy Storage
Phase Change Materials Research
article

Experimental study on thermal performance of porous phase change plates assisted air conditioning system in data centers

Hongwei Wu, Ruiyong Mao, Zujing Zhang, Xing Liang, Jiri Zhou, Hongli Xu, Zhongqiu Wang
article en

Abstract

The integration of phase change energy storage with cooling systems not only reduces the need for mechanical refrigeration in data centers (DCs), but also significantly enhances energy efficiency. However, research on the application location of phase change energy storage systems in DCs and the structural characteristics of system devices are limited. This paper combines the features of shell-and-tube and plate heat exchangers to design the porous phase change plate (PPCP) for use in DCs air conditioning systems and explores its cooling performance through experiments. The study employed single-factor and orthogonal experiments to analyze the effects of inlet air temperature, air velocity, aperture size and placement distance of the PPCP on the performance of the phase change heat device (PCHD) and evaluated the auxiliary effects of the device. The results indicate that: (1) The PCHD can reduce the air temperature by an average of 1.59 to 3.90 °C within 8 h. (2) The aperture size of the PPCP significantly affects the cooling performance of PCHD: a reduction in the PPCP aperture size by 2 cm results in an 8 % to 11 % enhancement in cooling performance. (3) In a comprehensive analysis of multiple factors, the primary and secondary factors of the PPCP are inlet air temperature > air velocity > aperture size > placement distance. (4) During high-temperature loads, the PCHD can assist in reducing mechanical energy consumption by up to 63 %. • Proposed to add a phase change energy storage functional section in air conditioning systems of data centers • Designed porous phase change plates for air conditioning system in data centers • Explored the influencing factors and laws of phase change heat device (PCHD) • PCHD can reduce temperature by 1.59–3.9 °C in 8 h.

Journal of Energy StorageVol. 141
University of Hertfordshire (GB), Guizhou University (CN), Kingston University London (GB), China South Industries Group (China) (CN)
Openalex Percentile: Top 66%
Phase Change Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.