The impact of healthy motion seating on lower‐limb blood flow and blood pressure response to simulated long‐haul air travel

Prolonged sitting inherent to long-haul air travel can acutely decrease lower-limb blood flow and increase brachial blood pressure. Healthy motion seating (HMS), which passively alters sitting interface pressure and posture, is a promising technology which may attenuate the deleterious effects of long-haul air travel. The aim of this study was to determine the impact of an innovative airplane passenger seat motion feature, aerospace HMS, on lower-limb blood flow and blood pressure in response to 6.5 h of simulated long-haul air travel. In a randomised cross-over design, 19 healthy adults completed a 6.5 h long-haul flight simulation in aerospace seating equipped with (HMS) and without (CON) healthy motion technology. Superficial femoral artery blood flow, brachial blood pressure, and perceptions of mood disturbance, pain and discomfort were measured before and after flight simulation. In linear mixed models there was a significant interaction (condition × time) effect for superficial femoral artery blood flow, with a decrease in lower-limb blood flow in CON (-22.4 mL/min; 95% CI: -2.41, -42.39; P = 0.032) but not HMS (3.7 mL/min; 95% CI: -16.3, 23.67; P = 0.720) across the 6.5 h flight simulation. There were no interaction, group nor time effects for blood pressure. Mood, pain and discomfort all worsened across the 6.5 h flight simulation (time, all P < 0.05), but there were no interaction nor group effects. The passive alterations in sitting interface pressure, posture and movement created by aerospace HMS can prevent prolonged sitting-induced reductions in local lower-limb blood flow typical of long-haul air travel.

Authors

Institutions

Publication Details

Journal
Experimental Physiology
Published
2025-11-04
DOI
https://doi.org/10.1113/ep092920
Primary Topic
Ergonomics and Musculoskeletal Disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of healthy motion seating on lower‐limb blood flow and blood pressure response to simulated long‐haul air travel

Keeron J. Stone, Mark Butlin, Barry J. McDonnell, Amira Tairi et al.
Experimental Physiology
Ergonomics and Musculoskeletal Disorders
article

The impact of healthy motion seating on lower‐limb blood flow and blood pressure response to simulated long‐haul air travel

Keeron J. Stone, Mark Butlin, Barry J. McDonnell, Amira Tairi, Eric D Johnston, Jane Lewis, Peter Sykes, T. Griffiths, Gisele J. Bentley
article en

Abstract

Prolonged sitting inherent to long-haul air travel can acutely decrease lower-limb blood flow and increase brachial blood pressure. Healthy motion seating (HMS), which passively alters sitting interface pressure and posture, is a promising technology which may attenuate the deleterious effects of long-haul air travel. The aim of this study was to determine the impact of an innovative airplane passenger seat motion feature, aerospace HMS, on lower-limb blood flow and blood pressure in response to 6.5 h of simulated long-haul air travel. In a randomised cross-over design, 19 healthy adults completed a 6.5 h long-haul flight simulation in aerospace seating equipped with (HMS) and without (CON) healthy motion technology. Superficial femoral artery blood flow, brachial blood pressure, and perceptions of mood disturbance, pain and discomfort were measured before and after flight simulation. In linear mixed models there was a significant interaction (condition × time) effect for superficial femoral artery blood flow, with a decrease in lower-limb blood flow in CON (-22.4 mL/min; 95% CI: -2.41, -42.39; P = 0.032) but not HMS (3.7 mL/min; 95% CI: -16.3, 23.67; P = 0.720) across the 6.5 h flight simulation. There were no interaction, group nor time effects for blood pressure. Mood, pain and discomfort all worsened across the 6.5 h flight simulation (time, all P < 0.05), but there were no interaction nor group effects. The passive alterations in sitting interface pressure, posture and movement created by aerospace HMS can prevent prolonged sitting-induced reductions in local lower-limb blood flow typical of long-haul air travel.

Experimental PhysiologyVol. 111(3)
National Theatre Wales (GB), Université Laval (CA), Cardiff University (GB), Cardiff Metropolitan University (GB), Macquarie University (AU)
Health and Care Research Wales
Openalex Percentile: Top 63%
Ergonomics and Musculoskeletal Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.