A comparison between clinical operative torque and in vitro torsional resistance

Operative torque indicates the real-time stresses exerted on Nickel-Titanium Rotary Instruments (NTRs) during clinical application, whereas torsional resistance denotes a file’s maximum capacity to withstand torsional stresses prior to fracture. A comprehensive understanding of both parameters is essential for enhancing instrument safety and informing the development of next-generation rotary systems. Consequently, the present study aimed to evaluate the “in vivo” operative torque values of new NiTi rotary instruments (I-file, Henry Schein Endodontics, China) and to compare these with the in vitro torsional resistance of each instrument. Twenty instruments, representing the following sizes (i-File 25.07, I-Follow 15.04, and I-Finish 25.04), were selected and divided into two groups. The first group (n=10 for each size) was evaluated for torsional resistance in accordance with ISO Standard 3630-1. The second group involved instruments used clinically to prepare a molar case. Data were collected and subjected to statistical analysis. The results demonstrated statistically significant differences among the three files in both tests; however, their behavior was similar. No values exceeded the torsional strength, indicating a proper balance between the two properties. The findings of the study confirmed an ideal distribution of intracanal operative loading, with all instruments exhibiting operative torque values below the maximum torque at failure.

Authors

Publication Details

Journal
Annali di stomatologia
Published
2025-01-01
DOI
https://doi.org/10.59987/ads/2025.4.371-374
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comparison between clinical operative torque and in vitro torsional resistance

Gambarini Gianluca
Annali di stomatologia
Endodontics and Root Canal Treatments
article

A comparison between clinical operative torque and in vitro torsional resistance

Gambarini Gianluca
article en

Abstract

Operative torque indicates the real-time stresses exerted on Nickel-Titanium Rotary Instruments (NTRs) during clinical application, whereas torsional resistance denotes a file’s maximum capacity to withstand torsional stresses prior to fracture. A comprehensive understanding of both parameters is essential for enhancing instrument safety and informing the development of next-generation rotary systems. Consequently, the present study aimed to evaluate the “in vivo” operative torque values of new NiTi rotary instruments (I-file, Henry Schein Endodontics, China) and to compare these with the in vitro torsional resistance of each instrument. Twenty instruments, representing the following sizes (i-File 25.07, I-Follow 15.04, and I-Finish 25.04), were selected and divided into two groups. The first group (n=10 for each size) was evaluated for torsional resistance in accordance with ISO Standard 3630-1. The second group involved instruments used clinically to prepare a molar case. Data were collected and subjected to statistical analysis. The results demonstrated statistically significant differences among the three files in both tests; however, their behavior was similar. No values exceeded the torsional strength, indicating a proper balance between the two properties. The findings of the study confirmed an ideal distribution of intracanal operative loading, with all instruments exhibiting operative torque values below the maximum torque at failure.

Annali di stomatologiaVol. 16(4)
Openalex Percentile: Top 54%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A comparison between clinical operative torque and in vitro torsional resistance — Gambarini Gianluca · Annali di stomatologia (2025) | TGRS Research Map | TGRS